© 2019 Pinnacle Climate Technologies, Inc.
Kerosene Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
®
OPERATION (CONT.)
Starting the Heater (Ignition):
1. Fill the tank with Kerosene or other approved fuel
until needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a three
prong (grounded) extension cord that is at least
1.8 meters long and is a minimum of 14 AWG
rating.
NOTE: On first ignition or after refueling, you may hear
a grinding sound just before ignition. This is the fuel
pump removing the air from the fuel line. Your heater
will start up within seconds. If it does not start repeat
start-up procedures with fuel gauge reading at least 1/2
tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these heaters are
protected by a fuse mounted in the PC board. If the
heater fails to ignite, check this fuse first and replace if
necessary. Also check the power source to be sure the
proper voltage is being provided to the heater.
1. Complete steps 1-3 above.
2. Push the power switch to the “ON” position. The
power indicator lamp will light and heater will
ignite (see Figure 10).
Stopping the Heater (Cool Down):
1. Turn the power switch to the “OFF” position.
Combustion will stop and the Cooling Cycle will
begin.
- 80-OFR: approx. 5 mins
- 125-OFR-A: approx 3 mins
When the Cooling Cycle is complete the fan will
stop running and it will be safe to unplug the
heater.
NOTE: Unplugging the heater before the Cooling Cycle
has been completed may cause overheating, possible
damage to the heater and heat plate.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has been
completed.
2. Follow all start-up procedures above.
Electrical Outlet (80-OFR Only):
-
Never plug an appliance with more than a 5 amp
rating into this outlet (see Figure 11).
-
Always keep outlet covered when not in use
Figure 10
Power Switch
Figure 11
Electrical Outlet
80-OFR Only
DO NOT disconnect
heater from power
source before cooling
cycle has been completed.
WARNING