![Pinnacle ProTemp PT-125-OFR-A Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/pinnacle/protemp-pt-125-ofr-a/protemp-pt-125-ofr-a_users-manual-and-operating-instructions_1557398010.webp)
10
© 2019 Pinnacle Climate Technologies, Inc.
Kerosene Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
®
MAINTENANCE (CONT.)
Service (Continued):
NOZZLES:
Nozzles should be cleaned or replaced at least once
per heating season. Contaminated fuel could make
this necessary immediately. To clean dirt from nozzle,
blow compressed air through nozzle front. It may be
necessary to soak nozzle in clean Kerosene or diesel
to help loosen any particles (see Figure 14a and 14b).
PHOTOCELL:
The photocell should be cleaned at least once per
heating season or more depending on conditions. Use
a cotton swab and water or alcohol to clean the lens
of the photocell.
Be certain to reinstall the photocell in proper position
as shown below (see Figure 15).
FILTERS:
The fuel filter and oil filter should be cleaned at
least twice per heating season by rinsing it in clean
Kerosene or diesel. Contaminated or old fuel could
make cleaning necessary immediately.
Figure 14a
Figure 15
Photocell
80-OFR Nozzle
125-OFR-A Nozzle
Figure 14b