If you choose “YES”, the system will be in stat. mode, when you use the hotkey, the sale subtotal of this key 
will be printed on label. And if you choose “NO”, you can do hotkey operation as normal. 

27.

 

stat Warnning? : Whether to set the stat. Warnning. Use arrow key to select “YES” or “NO”. 

28.

 

prn Tubtot: Press [Enter] to print the total label. 

29.

 

Prn ALL stat. plu: This operation can print stat. data of each hotkey. 

30.

 

clr stat.: Press [Enter] to clear stat.. 

31.

 

Z---LABEL  SELECT:  This  is  to  choose  the  label  paper  type.  There  are  two  types  of  label  paper,  one  is 
No-gap  paper,  and  the  other  is  gap  paper.  User  key  “

”  “

”  to  select  „YES‟  or  „NO‟.  „YES‟  for  No-gap 

paper, and „NO‟ for gap paper. Gap paper is the default label paper type. Only when you install the No-gap 
paper into the scale, you need to set this item to „YES‟. 

 

8.3

 

Function Lock 

PLU edit, Discount Program and tare functions can be locked by password and password of each function is 

independent and changeable. Password is set by background PC server and downloaded to every scale. 
Operation on the label scale is as followings: 

Note: Once you turn on the locked function, this function will be valid until the scale is warmly closed. 
 

Turn on the 

locked 

function 

1. Turn on the scale. 

2. Select the desired function key. 

Press  Discount  key  two  seconds  to  enter  discount  function,  the  system  prompts  to  input 

password, then input the safe password which is set by background PC server. 

Press  PLU  key  for  two  second  to  enter  PLU  editing  state,  the  system  prompts  to  input 

password, then input the safe password which is set by background PC server. 

Press  System  Set  key  for  one  second  to  enter  program  setting  state,  the  system  prompts  to 

input password, then input the safe password which is set by background PC server. 

Press  Tare key for one second to enter tare state, the system prompts to input password, then 

input the safe password which is set by background PC server. 

Press  Change  Price  key  for  one  second  to  enter  change  price  state,  the  system  prompts  to 

input password, then input the safe password which is set by background PC server. 

Lock 

these 

functions 
again. 

1. Press On/Off key for two seconds to warmly close the scale. 

2. Press On/Off key to open the scale. 

8.4

 

Lock Scale 

You can lock the scale by password, so that other people can‟t do any operation on the scale. 
Lock scale as the following method: 

Lock the scale 

1. Press Password key until the word “PASSW” appears on the LCD display. 

2. Input the eight-digit password by numeric keyboard. 

3. Press Password key and after hearing a “beep” sound to show the password has been set. 

Turn  on  the 
lock casually 

1. Turn on the scale. 

2. The LCD display “PASSW”. 

3. Input the eight-digit password, then press Password key to turn on the lock. 

Turn  on  the 
lock 
timelessly 

1. Turn on the scale. 

2. Press C key. 

3. Press Password key for two seconds until the word “PASSW” appears on the LCD display. 

4. Input the eight-digit password, then press Password key to turn on the lock. 

 

Содержание LS2C15

Страница 1: ...BARCODE LABEL SCALE SALES OPERATION MANUAL MODEL Pinnacle Technology Corp LS2R15 LS2R30 LS2C15 LS2C30 LS2N15 LS2N30...

Страница 2: ......

Страница 3: ...ently Change Price 21 6 6 2 Temporarily Change Price 22 7 SOME SIMPLE OPERATION 24 7 1 Copy price label 24 7 2 Print receipt 24 7 3 Normal Package 24 7 4 Package by Fixed weight 24 7 5 Package by Fixe...

Страница 4: ...STATEMENT Please refer to PC software management manual in attached CD about the PLU editing hotkey downloading label editing and parameter setting etc...

Страница 5: ...live commodity Code and package type and so on 15 Label can be printed in rotated position 16 Support 8 code Ean 13 code and 18 code and resolve the coding problem of live commodity 17 Special barcode...

Страница 6: ...6kg 15kg e 5g LS215 0kg 15kg e 5g LS21530 0kg 15kg e 5g 15kg 30kg e 10g Number of verification scale interval 3000 Printer Printer driver 24V Number of dots line 448dots per line Dot spacing 0 125mm...

Страница 7: ...3 LS2C LS2N...

Страница 8: ...4 3 APPEARANCE LS2R Printer Display Tray Hotkey Numerical key Function key Power switch LS2C Printer Display Tray Hotkey Numerical key Function key Power switch...

Страница 9: ...er Clearing pen Note If the printer head is dirty clean hot sensor head softly with the cleaning pen attached The cleaning pen is an alcohol pen please cover it immediately after you wipe the dirty of...

Страница 10: ...4 1 Install display pole 1 Take out the fix set 4 Put on fix set Connect the line and fix the 4 screws 2 Open the LCD cover 3 o 5 o and Mount the display pole 3 Cover the LCD then put on fix set like...

Страница 11: ...o as how to turn down it Note this key takes effect by the condition that the plug has connected and the power switch under the scale is turned on We suggest that you should use On Off key to turn On...

Страница 12: ...r for the first time 1 Open the side cover 2 Take out the printer and open the turnable printing assembly Conveying protection bolt 3 Rip off the first several labels 4 Insert the release paper to the...

Страница 13: ...oll the release paper in the rewinder axis as the direction of arrowhead 3 shows 3 Push the turnable printing assembly to the right position in the direction shown as the arrowhead 4 4 When every five...

Страница 14: ...ery suitable for label scale It is a kind of environment protecting material has suitable thickness high sensitivity and low price We can produce any kind of specification label paper to match your re...

Страница 15: ...Install the receipt paper cutter 2 Open the turnable printing assembly 3 Load the paper like the map shows directly lead the thermal paper to the paper outlet 4 Pay attention to adjust the paper fixin...

Страница 16: ...lose the turnable printing assembly 6 Close the side cover NOTE If you use thermal paper instead of label you should choose RECEIPT in System Set Please refer to Chapter 7 2 Print receipt Paper fixing...

Страница 17: ...hen you print linerless paper 1 Press System set for seconds to enter the related setting and then press key till the LCD display Gap paper and choose Yes and then press the key Print Enter to confirm...

Страница 18: ...upply first Do not disassemble assemble or adjust the printer if it is operating satisfactorily In particular do not carelessly loosen the screws holding various parts in place When servicing be sure...

Страница 19: ...15 Use a screwdriver to push the latch to the left side Lift up the printer...

Страница 20: ...16 2 Install a new one Install new printer by following the demount procedure in reverse order Pull out the cable...

Страница 21: ...RO state There is nothing on the pan Press ZERO key to let the weight zero and the ZERO signal will be on 3 Usage of Print key All of the following operations including Calculate by Weight Tare Operat...

Страница 22: ...1 6 4 Input LFCODE 10 of the onions through small keyboard 1 0 LLFCODE 1 6 10 00 5 Press PLU key PLU 2 000kg 1 50 3 00 Ignore this step if the LFCODE has 6 digits METHOD 3 operation for PLU without s...

Страница 23: ...lculate by Piece There are three kinds of operation methods The following operation of method 1 and method 2 is suitable for PLU already downloaded by background sever or pre edited on the scale And m...

Страница 24: ...f the cake 12 through small keyboard 1 2 LLFCODE 1 6 12 5 Press PLU key PLU 0 000Kg 3 00 30 00 Ignore this step if the LFCODE has 6 digits METHOD 3 operation for PLU without pre edited OPREATION KEY A...

Страница 25: ...operation such as normal operation or operation for pre edited PLU to proceed with the above operation 6 6 Change Price Change the unit price of a commodity There are two methods to change the unit p...

Страница 26: ...to Weight Unit price Total 1 Key in 10 10 cases via the numeric key 1 0 0 000kg 0 10 0 00 2 Press Unit key Unit 0 000kg 0 00 0 00 Display is back to the initial status 3 key in the new price 30 PCS g...

Страница 27: ...ION KEY ARROW DISAPLY REMARK Zero Auto Weight Unit price Total 1 Put the cherry weighted 1kg onto the scale 1 000kg 0 00 0 00 2 Key in LF code 13 via the numeric keypad 1 3 1 000kg 0 13 0 00 PLU with...

Страница 28: ...ware PLU manager 1 Start up the function of Auto and Price lock these two indicator light are lighting 2 Select PLU or input the unit price 3 Put the commodity to be packed on the pan and the label wi...

Страница 29: ...ing OPERATION KEY ARROW DISPLAY REMARK Zero Auto Fix Price Weight Unit Price Total 1 Put the fish on the pan 0 505kg 0 00 0 00 2 Press the hotkey 38 of the fish via PLU keyboard 3 8 0 505kg 0 00 35 35...

Страница 30: ...tal 1 Press hotkey 01 0 000kg 0 00 0 00 2 Put the apple on the pan and press hotkey 06 0 6 1 000kg 0 00 0 00 3 Put the orange on the pan and press hotkey 07 0 7 2 000kg 0 00 0 00 4 Put the grape on th...

Страница 31: ...kg Lb and Oz or PCS g PCS kg PCS Lb and PCS Oz 6 F SHELF Input the shelf time of PLU period from 0 to 365 means its unit is day period from 1000 to 9999 means its unit is hour e g input 60 which stand...

Страница 32: ...igits or 4 digits 14 D DENSITY Select printing density from 0 to 5 with arrow This scale supports print density class 0 to 5 0 is the lightest one of all and 5 is the thickest of all 15 Q PRINT DELMAR...

Страница 33: ...hich is set by background PC server Press PLU key for two second to enter PLU editing state the system prompts to input password then input the safe password which is set by background PC server Press...

Страница 34: ...the HUB SWITHCH can t identify the Crossover Cable when you use HUB SWITCH to connect the scale please use A Straight through Cable to replace the Crossover one PC MANAGER POS SERVER POS1 POS2 NETWAR...

Страница 35: ...sale account 120 Link32 sends end command 220 Link32 transfers one account to background 210 Background sends ACK command 102 Link32 download PLU change date to label scale 9 1 Handshaking Flowchart o...

Страница 36: ...or Command list Link32 background Code Description Type Length Remark 0201 Starting command Number 4 0202 ACK command Number 4 Command code Number 4 LFCode Number 6 Error code Number 4 0210 Link32 sen...

Страница 37: ...ge white blue blue white orange brown white white 2 line Connection order orange white orange green white blue blue white green brown white white 3 Plug peeling end A into 8 PIN PHONE connector as eit...

Страница 38: ...ng direction or covered by dust c Photoelectric board is bad d Photoelectric group of back photoelectric is bad Treatment a According to the following sequence adjust the scale Enter system Enter pape...

Страница 39: ...hange keyboard circuit 2 Key doesn t sound Reason a Key wire is not inserted well b Electric rubber of key press circuit board is not installed well c The replaced kit is bad Treatment a Check key wir...

Страница 40: ...he correct communication port b Confirm number set in Link32 is consistent with the number in the scale c Confirm the Netware wire is smooth and communication connecting header is used correctly There...

Страница 41: ...14 24 2 III 3 PPPPPPP 7 X C 15 25 2 IIIIII 6 X Q QQQ 4 C 16 26 2 IIIIII 6 X QQ QQ 4 C 17 27 2 IIIII 5 X QQ QQQ 5 C 18 28 2 IIIII 5 X QQQQ Q 5 C 19 29 2 IIIII 5 X QQQQQ 5 C 20 no print barcode 21 29 E...

Страница 42: ...4 C 92 DD 2 IIIIII 6 WWWWW UU UU 4 C 93 D 1 IIIIII 6 PPP PP 5 UUU UU 5 C 94 DD 2 IIIII 5 PPP PP 5 WW WWW C 95 DD 2 IIIIII 6 WWWWW UU UU 4 C Meaning of characters in the above list C CHECKSUM D Departm...

Страница 43: ...ey hotkey 11 hotkey 10 Only one select key 47key Switch key between Chinese character and English character 73 Switch hotkey between Chinese character and English character 5 Label editing key key bet...

Страница 44: ......

Страница 45: ......

Страница 46: ...DPSB01002EV LS2X 12...

Отзывы: