background image

14

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2020 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

LIMITED WARRANTY (5-YEAR MOTOR WARRANTY)

Pinnacle Climate Technologies, Inc.

 warrants this heater to 

the original retail purchaser only, to be free from defects in 
material and workmanship for a period of one (1) year from 
the date of initial purchase. This product must be properly 
installed, maintained and operated in accordance with the 
instructions provided.

Pinnacle Climate Technologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 
or distributor.  Therefore, you should keep your sales slip, 
invoice or cancelled check from the original purchase.  
This Limited Warranty shall be limited to the repair or 
replacement of parts, which prove defective under normal 
use and service within the warranty period, and which 
Pinnacle Climate Technologies , Inc.

 shall determine at its 

reasonable discretion. 

This warranty does not apply to products purchased for 
rental use. 

This Limited Warranty does not cover any failures or 
operating difficulties due to normal wear and tear, accident, 
abuse, misuse, alteration, misapplication, improper 
installation or improper maintenance and service by you 
or any third party.  Failure to perform normal and routine 
maintenance on the heater, shipping damage, damage 
related to insects, birds or animals of any kind, and damage 
due to weather conditions are also not covered.   
In addition, the Limited Warranty does not cover damage 
to the finish, such as scratches, dents, discoloration, rust or 
other weather damage, after purchase. 

All transportation costs for the return of damaged product 
or parts will be the responsibility of the purchaser. Upon 
receipt of damaged item, Pinnacle Climate Technologies, 
Inc. 

will examine the item and determine if defective. 

Pinnacle Climate Technologies, Inc. 

will repair or replace 

and return the item, freight pre-paid. 

If Pinnacle Climate Technologies, Inc. finds the item to 
be in normal operating condition, or not defective the item 
will be returned freight collect. This Limited Warranty is 
in lieu of all other express warranties. Pinnacle Climate 
Technologies, Inc.

 disclaims all warranties for products that 

are purchased from sellers other than authorized dealers or 
distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 
WARRANTY EXPIRES, Pinnacle Climate Technologies, 
Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle 
Climate Technologies, Inc. 

SHALL HAVE NO LIABILITY 

WHATSOEVER TO PURCHASER OR ANY THIRD PARTY 
FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, 
OR CONSEQUENTIAL DAMAGES. Pinnacle Climate 
Technologies, Inc. 

assumes no responsibility for any defects 

caused by third parties. This Limited Warranty gives the 
purchaser specific legal rights; a purchaser may have other 
rights depending upon where he or she lives. Some states 
do not allow the exclusion or limitation of special, incidental 
or consequential damages, or limitations on how long a 
warranty lasts, so the above exclusion and limitations may 
not apply to you.  

Pinnacle Climate Technologies, Inc. 

does not authorize any 

person or company to assume for it any other obligation 
or liability in connection with the sale, installation, use, 
removal, return or replacement of its equipment, and no 
such representations are binding on Pinnacle Climate 
Technologies, Inc.

Always be sure to specify the model number and serial 
number when making any claim with Pinnacle Climate 
Technologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. It will be a 
series of 9 digits. For Example: 131234956. Have your Serial Number ready before calling customer 
service at 800-641-6996.

 

Serial Number Label

XX-X-XXX

XXX

 

Содержание Master MH-140T-KFA

Страница 1: ...R IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTER...

Страница 2: ...NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep com bustibles such as building materials paper or cardboard a safe dis tance away from the...

Страница 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Страница 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Страница 5: ...Extension Cord Wrap Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Power Cord Fuel Tank Power Reset Switch Thermostat Knob 80T KFA Only Lamp Lower Shell Upper Shell Power Cord Drain Bolt Fuel Tank Pres...

Страница 6: ...ght or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should...

Страница 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Страница 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Страница 9: ...E While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T...

Страница 10: ...TO A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digi...

Страница 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Страница 12: ...A POWER SOURCE 2020 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 39 32 33 34 28 27 5 31 30 24 26 36 35 37...

Страница 13: ...70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Filter Kit 70 054 010...

Страница 14: ...eight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of al...

Страница 15: ...ARA USO ESTERIOR Y USO INTERIOR PERO S LO EN REAS BIEN VENTILADAS EL USO EN INTERIORES S LO SE PERMITE PARA CALEFACCI N TEMPORAL DE EDIFICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MOD...

Страница 16: ...P65Warnings ca gov ADVERTENCIA NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de c...

Страница 17: ...seno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los prod...

Страница 18: ...de env o Nota Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente Ilustrado con el cable opcional Enrolladores Enrolladores de cable Opcional Asa 1 Tornillos de 10 m...

Страница 19: ...parador Llanta Soporte del eje ESPECIFICACIONES N de modelo 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA Capacidad nominal BTU H kWh 45 000 13 2 80 000 23 4 140 000 41 190 000 55 7 215 000 63 Consumo de...

Страница 20: ...una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse nicamente en un contenedor azu...

Страница 21: ...ra es inferior a 0 F 18 C la pantalla mostrar LO Baja Cuando la temperatura es superior a 99 F 37 C la pantalla mostrar HI Alta Entre 0 F 18 C y 99 F 37 C la pantalla mostrar la temperatura real Apaga...

Страница 22: ...RO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hacer que s...

Страница 23: ...alentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de la bomba Modelo...

Страница 24: ...ITOR 10UF 250 VCA CA 120 V 60 Hz INTERRUPTOR DE ENCENDIDO CONTROL DE L MITE AMARILLO FUSIBLE 8 A 125 VCA VERDE TIERRA BLANCO PCI DE CONTROL LUZ LED TERMOSTATO CONTROL DE TEMP FOTOC LULA SENSOR DE AMBI...

Страница 25: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Страница 26: ...NTE DE ALIMENTACI N 2020 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno VISTA DETALLADA S lo 45 KFA 80T KFA S lo 140T KFA 215T KFA 13 10 12 8 11 9 29...

Страница 27: ...0 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 Cubierta de la bomba 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70...

Страница 28: ...Pinnacle Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada...

Отзывы: