UPS PIco HV3.0A Firmware Code 040 Print Date 18.08.2017
Designed and Manufactured by PiModules and ModMyPi
www.pimodules.com www.modmypi.com
Hour
= 0x09;
means it will start at 09-hour morning time
Minute
= 0x59;
means it will start exactly at 09:59
0x6d -> ETR SAS Actions Running Time Stamp
Action Duration
= 0003;
means it will run for 3 minutes (2 minutes longer than
Raspberry Pi® in the 1
st
Example)
Action Repetition Time
= 00;
means it will be not repeated within the same
sequence (any value is allowed if Action Multiplier =
0x01)
Action Multiplier
= 01;
means it will happen 1 time within the same
Sequence
Sequence Repetition Time
= 24;
means this (above described) sequence (that hold
one action) will be repeated every day (every 24
hours).
0x6e -> ETR SAS Actions Stamp
Action BR_Set
= 0x01;
means that Action of this Scheduler will be
Bi-Stable
Relay Set
and
(after Action Duration Time)
Reset
0x6f -> ETR SAS Events Stamp
Not involved. Keep all values 0x00.