Installation
7
The cross-section area of the AC wires must be at least 0.75mm2 (18 AWG).
The wires must be tied together with a cable tie. The flammability of the
cable tie must be UL 94 V-2 or better.
The cable hole on the box should have a grommet or bushing.
Initializing and setting the time
To program the TD-600, you will need a PIMA technician keypad or LCD keypad, such as the
RXN-400, and a special 4-wire cable with Molex connector (P/N 3411007).
Connect the keypad to the KEYPAD terminal on the SAT-6
1
. See Figure 1 on page 4. Upon
connecting the TD-600 to power, a long tone is sounding and the red Fault LED is blinking,
followed by the next screen series:
Accurate system time is essential for the routine operation of the TD-600. To set the time, follow
the next sequence:
Master code (default: 5555)
current time (HH:MM)
current date (YY:MM:DD)
.
To correct data,
/
.
1
If you use the RXN-400/410/800 keypads, you will need to open the back cover to access the PCB.
Keypad Ver.
1.15
Keypad ID:0
Starting
Please wait...
Clock 00:00
------
. . . .
. . . .
HOUR
0 :0
ENTR
YEAR MONTH DAY
16 1 1
ENTR