TD-600/SAT-6 Installation Guide
4
The SAT-6 module
Figure 1.
The SAT-6 diagram
No.
Terminal/
Connector
Description
1
(+)/(-)
Power supply for PIR/ultrasonic/etc., detectors
2
Z1-Z6
6 inputs for dry contact detectors & (-) terminal
3
KEYPAD
A Molex connector for quick connection of the technician keypad
4
EGND
Earth Ground terminal. Can be used in areas of severe electrical
activity (abnormal levels of lightning or electrical discharge).
When using PIMA’s integrated transformer, earth ground is not
required. Only when using external transformer and lightning
conditions are severe, the EGND terminal can be used.
Connect the terminal to earth grounds, such as metal cold water
pipe or AC power outlet ground
5
Transmitter
A connector to the TRV/TRU-100 long range radio transmitters and the
GSM-200 cellular module
6
Backup
Battery wires
Red: (+)
Black : (-)
7
AC
14-16 VAC Voltage input
The cross-section area of the AC cable must be at least 0.75mm
2