background image

PSSu H m F DP ETH SD

Operating Manual­1002323­EN­04

Control system PSSuniversal multi

Содержание PSSuniversal multi PSSu H m F DP ETH SD

Страница 1: ...PSSu H m F DP ETH SD Operating Manual 1002323 EN 04 Control system PSSuniversal multi...

Страница 2: ...es may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the s...

Страница 3: ...pply voltage 11 4 3 1 Function description 11 4 3 2 Current load capacity 12 4 4 Integrated protection mechanisms 12 4 5 SD card 13 4 6 Reset button 13 4 7 PROFIBUS DP 14 4 7 1 Connection to PROFIBUS...

Страница 4: ...ges 22 8 2 Display elements 22 8 2 1 MBUS 23 8 2 2 SD CARD 24 8 2 3 FS RUN 25 8 2 4 DIAG 26 8 2 5 FS FORCE 27 8 2 6 SF BF 28 8 2 7 5V 24V 28 8 2 8 X3 LNK X3 TRF 29 Section 9 Technical details 30 9 1 S...

Страница 5: ...tion This documentation is intended for instruction and should be retained for future reference 1 2 Definition of symbols Information that is particularly important is identified as follows DANGER Thi...

Страница 6: ...ation in which the product or devices could be dam aged and also provides information on preventive measures that can be taken It also highlights areas within the text that are of particular import an...

Страница 7: ...the naming data and or device project from the SD card to the device memory Supply voltage Integrated supply voltage for periphery supply and module supply Module supply is buffered for 20 ms if the s...

Страница 8: ...trip see below for details 4 Status LEDs 5 SD card 6 Reset button 7 Supply voltage connection module and periphery supply The labelling strip contains the following information Order number Serial num...

Страница 9: ...sion download from www pilz de 3 2 Safety regulations 3 2 1 Use of qualified personnel The products may only be assembled installed programmed commissioned operated maintained and decommissioned by co...

Страница 10: ...made e g exchanging components on the PCB boards soldering work etc 3 2 3 Disposal In safety related applications please comply with the mission time TM in the safety re lated characteristic data When...

Страница 11: ...created in Multi programming For safety related applications the processor section is designed with multi channel di versity The control system communicates with the input and output modules via the l...

Страница 12: ...ill be entered in the dia gnostic list Periphery supply The current load is the total current consumption of the sensors actuators and test pulses supplied via the input output modules The periphery s...

Страница 13: ...ror The SD card has a locking mechanism which protects it from being removed from the card holder uninten tionally The SD card can also be sealed to protect it from manipulation whether acci dental or...

Страница 14: ...range 0D 125D If station address 126D is set via the DIP switch the address can be assigned via the Master The Set Slave Address com mand SSA must be run for this purpose The station address is set a...

Страница 15: ...15 Firmware update The connection is established via a RJ45 socket The Ethernet interface is configured in PAS4000 see description in chapter Network in PAS4000 s online help 4 8 2 RJ45 connection ca...

Страница 16: ...ouching the product e g by touching an earthed conductive sur face or by wearing an earthed armband 5 2 Dimensions 130 mm 5 19 50 mm 1 97 3 1 mm 0 12 56 2 mm 2 21 125 6 mm 4 94 83 3 mm 3 28 79 1 mm 3...

Страница 17: ...lation Operating Manual PSSu H m F DP ETH SD 1002323 EN 04 17 Make sure that the locking mechanisms 3 are pushed downwards connecting the module firmly to the mounting rail Schematic representation 1...

Страница 18: ...ting resistors with voltage 5 VDC INFORMATION The two data lines are also called A and B on PROFIBUS Always connect the A line RxD TxD N to the A lines of all the other PROFIBUS subscribers The B line...

Страница 19: ...al PSSu H m F DP ETH SD 1002323 EN 04 19 RJ45 socket 8 pin PIN Standard Crossover 8 1 1 TD Transmit RD Receive 2 TD Transmit RD Receive 3 RD Receive TD Transmit 4 n c n c 5 n c n c 6 RD Receive TD Tra...

Страница 20: ...Function Description Earth the 0 V supply on the periphery supply or monitor each supply group for earth faults The connection of the 0 V supply to the central earth bar or earth fault monitor must be...

Страница 21: ...dule Supply Infeed for Periphery Supply 0 V DC 24 V DC N L1 N L1 Connect to the 0 V supply and earth at a single point X1 X2 24V 24V 0V 0V 24V 0V 6 A 10 A Common power supply for module supply and per...

Страница 22: ...the electronic or compact modules in a PSSu system are signalled to the head module and entered in the diagnostic table and diagnostic log You can read the head module s diagnostic table and diagnosti...

Страница 23: ...ning No modules present Green FS and ST module bus are operating without fault Red Operating state Safe condition of all FS outputs on the PSSu system or Unable to locate at least one module e g a mod...

Страница 24: ...supply is missing Red SD card is missing or SD card not recognised or SD card defective Green Naming data and device project on the PSSu system and SD card match Product type on the SD card does not m...

Страница 25: ...Operating state FS resource in RUN condition with error Task in TERMINATED condition or Task in STOP condition At least one FS resource task is not running The project is licensed Orange Operating st...

Страница 26: ...ing Green No message of Error or Warning severity is present for the device Device diagnostic list and device diagnostic log are being prepared Red A message of Error severity is present for at least...

Страница 27: ...al PSSu H m F DP ETH SD 1002323 EN 04 27 8 2 5 FS FORCE The FS FORCE LED shows the status of forcing on the FS resource Colour Status Meaning Forcing on the FS resource is inactive Yellow Forcing on t...

Страница 28: ...Configuration faulty Red Error in the head module Green Data transmission error free 8 2 7 5V 24V The 5 V LED shows the status of the module supply Colour Status Meaning No supply voltage for module...

Страница 29: ...net SafetyNET p interfaces The interface is assigned two LEDs at the head module Various operating and fault statuses on the Ethernet SafetyNET p interface are displayed via the LEDs X3 LNK Colour Sta...

Страница 30: ...No OPC Server No Programming IEC 61131 programming No Multi programming Yes Non volatile variables No Electrical data Supply voltage for Module supply Voltage 24 0 V Kind DC Voltage tolerance 30 25 Ma...

Страница 31: ...in cycle time FS tasks 10 ms Working memory RAM 64 MB Memory for the user program per resource 2 MB Removable data medium Type SD card External communication Max number of IP connections 32 Modbus TCP...

Страница 32: ...60068 2 14 EN 60068 2 2 EN 60068 2 30 EN 60068 2 78 Ambient temperature Temperature range 0 60 C Storage temperature Temperature range 25 70 C Climatic suitability In accordance with the standard EN 6...

Страница 33: ...sleeve 0 25 1 00 mm 24 16 AWG 2 core with the same cross section flexible without crimp connectors or with TWIN crimp connectors 0 20 1 50 mm 24 16 AWG Torque setting with screw terminals 0 50 Nm Cond...

Страница 34: ...1 Product Product type Features Order no PSSu H m F DP ETH SD Head module with PROFIBUS DP and an Ethernet interface base type 312 060 10 2 Accessories Terminals Product type Features Order no PSSu A...

Страница 35: ...mo PMCprotego PMCtendo PMD PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would poi...

Отзывы: