Technical Details
Operating Manual PSSu K F INC
1001688-EN-09
31
8
Technical Details
General
Approvals
CE, EAC (Eurasian), KOSHA, TÜV, cULus Listed
Application range
Failsafe
Module's device code
0324h
Number of ST input bits
64
Number of ST output bits
32
Number of ST status bits
8
Number of ST control bits
8
Application in system environment B
From FS firmware version, head modules
1.0.0
Electrical data
Internal supply voltage (module supply)
Module's power consumption
0,79 W
Periphery's supply voltage (periphery supply)
Voltage range
16,8 - 30 V
Module's current consumption with no load
15 mA
Module's power consumption with no load
0,37 W
Max. power dissipation of module
1,2 W
Incremental encoder input
Number of counter inputs
1
Type of counter inputs
Incremental encoder
Signal at counter inputs A and B and/or C
Differential signal (RS 422)
Permitted low signal range on LATCH/GATE/
STATUS signals
-3 - 5 V
Permitted high signal range on LATCH/GATE/
STATUS signals
11 - 30 V
Typ. input current of the LATCH and/or GATE and/or
STATUS signals at low level
0 mA
Typ. input current of the LATCH and/or GATE and/or
STATUS signals at high level
4 mA
Max. number of bits on the counter input
32 Bit
Evaluation of counter pulses
1x, 2x, 4x
Phase offset between differential signals A and B
90 deg
Phase offset tolerance
30 deg
Maximum cutoff frequency
5 MHz
Time constant of input filter on LATCH signal
50 µs
Time constant of input filter on GATE signal
50 µs
Time constant of input filter on STATUS signal
50 µs
Typ. processing time
0,1 ms
Potential isolation between input/output and periphery
supply
yes
Potential isolation between input/output and voltage
for the internal module bus
yes