PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
30
Electrical data
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
40 nF
PNOZmulti, PNOZelog, PSS
70 nF
No-load current
40 mA
Inputs
Number
2
Voltage at inputs
24 V DC
Input current range
5 mA
Semiconductor outputs
OSSD safety outputs
2
Signal outputs
1
Switching current per output
500 mA
Breaking capacity per output
12 W
Short circuit-proof
yes
Residual current at outputs
250 µA
Voltage drop at OSSDs
1,5 V
Conditional rated short circuit current
100 A
Lowest operating current
0 mA
Utilisation category in accordance with EN 60947-1
DC-12
Times
Test pulse duration, safety outputs
450 µs
Switch-on delay
after UB is applied
1,6 s
Inputs typ.
20 ms
Inputs max.
35 ms
Actuator typ.
500 ms
Delay-on de-energisation
Inputs typ.
20 ms
Inputs max.
35 ms
Actuator typ.
25 ms
Actuator max.
260 ms
Risk time in accordance with EN 60947-5-3
260 ms
Supply interruption before de-energisation
15 ms
Simultaneity, channel 1 and 2 max.
∞
Environmental data
Temperature of metal surface at ambient temperat-
ure: 25 °C
60 °C
Ambient temperature
In accordance with the standard
EN 60068-2-14
Temperature range
-25 - 55 °C
Storage temperature
In accordance with the standard
EN 60068-2-1/-2
Temperature range
-25 - 70 °C