PSEN op3.1/3.2
Operating Manual PSEN op3.1/3.2
1003607-EN-02
5
Unit viewer: receiver
[4]
[1]
[2]
[3]
[5]
[6]
[7]
[8]
[4]
[1]
[2]
[3]
[5]
[6]
[7]
[8]
Connector plug block rotated on the back of
the unit
Connector plug block rotated on the bottom
of the unit
}
[1]: LEDs for status display (on transmitter only)
}
[2]: LED to display operating status
}
[3]: Control for setting the sensitivity
}
[4]: Retention spring for releasing the rotatable connection
}
[5]: Slot (through hole) for attachment and horizontal adjustment
}
[6]: Through hole for attachment
}
[7]: Through hole for attachment
}
[8]: Rotatable connector plug block
Wiring
}
must be followed.
}
Use copper wiring with a temperature stability of 55 °C.
}
The supply voltage must be provided from a power supply. Use a protection class II
power supply in accordance with the regulations for extra low voltages with safe separ-
ation.
a
Wire the outputs from the receiver to the inputs provided on a safety light grid or control
system for external muting sensors.
Receiver
Assignment of the 4-pin
M12 male connector
1
2
3
4
PIN
1:
2:
3:
4:
Function
+10 ... 30 VDC
Output NC
0 V
Output NO
Wire colour
brown
white
blue
black