![Pilz PSEN ma1.4-10 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/pilz/psen-ma1-4-10/psen-ma1-4-10_operating-manual_1556984018.webp)
PSEN ma1.4p-59
Operating Manual PSEN ma1.4p-59
1003594-EN-06
| 18
Adjustment
}
The safety switch may only be used with the corresponding actuator PSEN ma1.4-10mm.
}
Always test the function with a connected evaluation device.
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed according to the specifications
. Operating distances may deviate if other arrangements are used.
Note the maximum permitted lateral and vertical offset (see
).
Dimensions in mm
34,3
M8
27,1
18
37
26,4
22
19
4,5
R8
Ø 8
37
22
4,5
14,4
18
14,4
Technical details
General
Certifications
CE, EAC (Eurasian), TÜV, cULus Listed
Sensor's mode of operation
Magnetic
Coding level in accordance with EN ISO 14119
Low
Design in accordance with EN ISO 14119
4
Classification in accordance with EN 60947-5-3
PDDB
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-20 %/+20 %
Max. switching frequency
1 Hz