![Pilz PSEN ma1.4-10 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/pilz/psen-ma1-4-10/psen-ma1-4-10_operating-manual_1556984015.webp)
PSEN ma1.4p-59
Operating Manual PSEN ma1.4p-59
1003594-EN-06
| 15
}
Safety switches and actuators
– Should be kept away from iron swarf
– Should not be exposed to strong magnetic fields
}
Prevent the safety switch and actuator being exposed to heavy shock or vibration.
}
Make sure that the safety switch and actuator cannot be used as an end stop.
}
Circumvention of the safety switch in a reasonably foreseeable manner must be preven-
ted.
}
Please note the installation measures in accordance with EN ISO 14119 for a proximity
switch type 4 with coding level Low.
}
Alignment errors of the guard must not adversely affect the safety function of the guard.
}
The assured operating distance S
ao
and the assured release distance S
ar
must be tested
under real conditions.
}
Do not apply any installation tools (e.g. Pliers) on the surfaces of the switch.
Installation type 1
}
1. Cut the thread (M4) in the required position.
}
2. Use a screw to fix the sensor.
}
3. Attach the second screw to the sensor. (Important: do not tighten the screws). Attach
the screws for the actuator, maintaining the distance between the screw head and the
plate: ca. 3 ... 6 mm.
}
4. Align actuator to sensor.
INFORMATION
The inscribed area on the actuator (sensing face) should face the sensor.
}
5. Slide the actuator on to the screws.
}
6. Align sensor and tighten screws with max. 0,8 Nm.
}
7. Align actuator and tighten screws with max. 0,8 Nm.
}
8. Close used mounting holes using seal (1) or (4) (see
).
}
9. Close unused mounting holes using seal (2) (see
Diagram [
}
10. Close mounting holes on the sensing face using seal (3) (see
}
11. Installation of sensor and actuator is now complete.