PSEN cs4.1n
Operating Manual PSEN cs4.1n
22180-EN-05
17
Safety switches PSEN cs4.1 with actuator PSEN cs2.1
1. Drill holes in the mounting surface to secure the actuator and safety switch (see
2. Use two screws to fix the safety switch in place. Do not fully tighten the 2nd screw on
the safety switch.
3. Attach the screws for the actuator, leaving a distance of 3 … 6 mm between the screw
head and plate.
4. Fix the actuator.
The arrows on the labelled surfaces of the safety switch and actuator must face each
other. Align the actuator and tighten the screws.
5. Align the safety switch and tighten the screws.
Adjustment
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed facing each other in parallel. Operating dis-
tances may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
and