![Pilz PSEN cs2.13p ATEX Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/pilz/psen-cs2-13p-atex/psen-cs2-13p-atex_operating-manual_1556967009.webp)
PSEN cs2.13p ATEX
Operating Manual PSEN cs2.13p ATEX
21133-EN-17
| 9
}
The connector should be protected from accidental loosening (e.g. using a cable tie).
}
The IP protection type (see
Technical details [
24]
) has been determined in accord-
ance with DIN EN 60529 with a safety switch that is as new.
Unit features
}
Transponder technology for presence detection
}
Pilz coding type: fully coded
}
Dual-channel operation
}
2 safety inputs for series connection of multiple safety switches
}
2 safety outputs
}
Safety Device Diagnostics (SDD)
– Safety Device Diagnostics can be used to poll sensor information, to perform actions
and to read configuration parameters
– Manipulation protection in accordance with ISO 14119 (chap. 7.2.d) is possible by
verifying the short name of the actuator through the controller via SDD communica-
tion
}
Diagnostic input for Y1 for Safety Device Diagnostics (SDD)
}
Signal output/diagnostic output Y32 for Safety Device Diagnostics
}
LED display for:
– State of the actuator
– State of the inputs
– Supply voltage/fault
}
4 directions of actuation
Function description
The safety outputs may have a high or low signal, depending on the position of the actuator
and the signal status of the inputs.
In a safe condition the safety outputs are in the OFF state.
Electrical states of the inputs and outputs (when switch is ready for operation:
Power/Fault LED is green):
Actuator in
the re-
sponse
range
Safety input
S11
Safety input
S21
Safety out-
put 12
Safety out-
put 22
Signal out-
put Y32
(without use
of the SDD)
Yes
High
High
High
High
High
Yes
Low
Low
Low
Low
High
No
x
x
Low
Low
Low
Yes
High
Low
High
Low
High
Yes
Low
High
Low
High
High
x: High or low signal