![Pilz PSEN cs2.13p ATEX Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/pilz/psen-cs2-13p-atex/psen-cs2-13p-atex_operating-manual_1556967027.webp)
PSEN cs2.13p ATEX
Operating Manual PSEN cs2.13p ATEX
21133-EN-17
| 27
Mechanical data
Operating distances
Assured operating distance Sao
15 mm
Typical operating distance So
21 mm
Assured release distance Sar
40 mm
Typical release distance Sr
32 mm
Repetition accuracy switching distances
10 %
Change of operating distance with temperature
changes
+-0,01mm/°C
Typ. Hysteresis
3 mm
Min. distance between safety switches
400 mm
Sensor flush installation in accordance with EN
60947-5-2
Yes, follow installation guidelines
Connection type
M12, 8-pin male connector
Material
Top
PBT
Max. torque setting for fixing screws
1 Nm
Dimensions
Height
75 mm
Width
40 mm
Depth
40 mm
Actuator dimensions
Height
11 mm
Width
40 mm
Depth
40 mm
Weight of safety switch
130 g
Weight of actuator
20 g
Weight
150 g
Where standards are undated, the 2016-10 latest editions shall apply.
Safety characteristic data
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
2-ch. OSSD
PL e
Cat. 4
SIL CL 3
4,10E-09
–
1,10E-04
20
Explanatory notes for the safety-related characteristic data:
}
The SIL CL value in accordance with EN 62061 corresponds to the SIL value in accord-
ance with EN 61508.