Pilz PSEN cs2.13p ATEX Скачать руководство пользователя страница 1

PSEN cs2.13p ATEX

Operating Manual-21133-EN-17

}

PSEN sensor technology

Содержание PSEN cs2.13p ATEX

Страница 1: ...PSEN cs2 13p ATEX Operating Manual 21133 EN 17 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...nd liability 8 Disposal 8 For your safety 8 Unit features 9 Function description 9 Safety Device Diagnostics 10 Operating distances 11 Lateral and vertical offset 12 Wiring 12 Terminal assignment conn...

Страница 4: ...Contents Operating Manual PSEN cs2 13p ATEX 21133 EN 17 4 EC declaration of conformity 30...

Страница 5: ...portant is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that...

Страница 6: ...n accordance with EN 60947 5 3 PDDB with the actuator PSEN cs2 1 EN 62061 SIL CL 3 EN ISO 13849 1 PL e Cat 4 EN ISO 14119 Coding level High type 4 The safety switch may only be used with the correspon...

Страница 7: ...anual of a passive junction for example PSEN ix2 F4 code PSEN ix2 F8 code PDP67 F 4 code PSEN Y junction You will need to be conversant with the information in these documents in order to fully un der...

Страница 8: ...ury and death You should prevent any possibility of the interlocking device being manipulated through the use of a spare actuator Keep the substitute actuator in a safe place and protect it from unau...

Страница 9: ...fying the short name of the actuator through the controller via SDD communica tion Diagnostic input for Y1 for Safety Device Diagnostics SDD Signal output diagnostic output Y32 for Safety Device Diagn...

Страница 10: ...activated and data is read If no fieldbus module of the SDD is used the diagnostic input Y1 is not used Signal output diagnostic output Y32 The status of the actuator is output If a fieldbus module of...

Страница 11: ...s there are the following diagnostic options for the fieldbus module for simple wiring Information is passed on via the fieldbus module directly to the network Mappings of the signal outputs to the se...

Страница 12: ...ust be followed The max cable length lmax in the input circuit is calculated from the max cable capacitance at the safety outputs see Technical data 24 the minimum permitted supply voltage at the sens...

Страница 13: ...60079 14 When connecting in series consider the requirements of manipulation protection and the protection against bypassing or from overriding the safety switch EN ISO 14119 Ensure that the connecto...

Страница 14: ...cs is described in the System Description Safety Device Diagnostics CAUTION Do not connect the signal output to 0 V If the signal output Y32 is connected to 0 V the safety switch may be dam aged as a...

Страница 15: ...other sensors Maximum number of PSENcode sensors switched in series connections for SIL CL 3 using SDD PSENcode large design PSEN cs1 xp cs2 xp 8 When using other SDD compatible sensors the number mu...

Страница 16: ...switches The may delay on de energisation is composed of max delay on de energisation actuator n 1 x max delay on de energisation of the inputs delay on de energisation of the evaluation device When m...

Страница 17: ...gram series connection without SDD Actuator Actuator Control System Evaluation Device Safety switch1 Actuator Safety switch 2 Safety switch n Ex area Non Ex area FS Fail Safe S21 S11 12 A1 A2 22 0 V 2...

Страница 18: ...12 22 A1 A2 A1 A2 Y1 Y1 Y1 Y32 Y32 Y32 Tx Rx Actuator Safety switch Evaluation device Fieldbus module Non Ex area Ex area Actuator Actuator Safety switch Safety switch Connection to Pilz evaluation d...

Страница 19: ...to the respective evaluation device is described in the operating manual for the evaluation device Make sure that the connection is made in accordance with the specifications in the operating manual f...

Страница 20: ...response range To teach in a new actuator A maximum of 8 learning procedures are possible 1 The actuator that is to be taught in must be brought into the safety switch s response range as the only tra...

Страница 21: ...ipotential bonding in case of a risk of charging Make sure that the earthing is in accordance with the specifications in EN 60079 14 CAUTION Potential loss of safety function due to changed device pro...

Страница 22: ...efined angle of the cable routing CAUTION Possible loss of the safety function by changing the release distance Sar with non flush installation Installing the safety switch non flush within electrical...

Страница 23: ...monthly function test on the safety switch and actuator Always test the function with a connected evaluation device The safety function may only be checked by qualified personnel Refer to the notes o...

Страница 24: ...Power Fault LED lights up red Error message Remedy Rectify fault and interrupt power supply Please note the different times for The switch on delay after UB is applied The recovery time of the sensor...

Страница 25: ...puts No load PNOZ with relay contacts 40 nF PNOZmulti PNOZelog PSS 70 nF No load current 50 mA Inputs Number 2 Voltage at inputs 24 V DC Input current range 5 mA Max overall cable resistance Rlmax Sin...

Страница 26: ...ith the standard EN 60068 2 14 Temperature range 25 40 C Max at max operating height 40 C Max at max operating height 2000 m 40 C Storage temperature In accordance with the standard EN 60068 2 1 2 Cli...

Страница 27: ...r fixing screws 1 Nm Dimensions Height 75 mm Width 40 mm Depth 40 mm Actuator dimensions Height 11 mm Width 40 mm Depth 40 mm Weight of safety switch 130 g Weight of actuator 20 g Weight 150 g Where s...

Страница 28: ...e this equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonab...

Страница 29: ...bracket cable fix Mechanical protection against defeat protecting against unau thorised cable disconnection or damage for safety switches PSENcode cs1 2 PSENcode cs5 6 M12 PSENslock 532 112 Cable Prod...

Страница 30: ...e VA Decentralised passive junction V2A ring nut 773 613 Safety Device Diagnostics Product type Features Connection type Order no PSEN ix2 F4 code Interface for connecting max 4 PSEN safety sensors Sp...

Страница 31: ...anual PSEN cs2 13p ATEX 21133 EN 17 31 The complete EC Declaration of Conformity is available on the Internet at www pilz com downloads Representative Norbert Fr hlich Pilz GmbH Co KG Felix Wankel Str...

Страница 32: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Отзывы: