PSEN 4.2a/b/p/M12
Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02
24
Times
541209
541210
Delay-on de-energisation
Inputs typ.
15 ms
15 ms
Inputs max.
20 ms
20 ms
Actuator typ.
40 ms
40 ms
Actuator max.
260 ms
260 ms
Supply interruption before de-ener-
gisation in the input circuit
10,0 ms
10,0 ms
Simultaneity, channel 1 and 2
∞
∞
Environmental data
541209
541210
Ambient temperature
In accordance with the standard
EN 60068-2-14
EN 60068-2-14
Temperature range
-25 - 70 °C
-25 - 70 °C
Storage temperature
In accordance with the standard
EN 60068-2-1/-2
EN 60068-2-1/-2
Temperature range
-25 - 70 °C
-25 - 70 °C
Climatic suitability
In accordance with the standard
EN 60068-2-78
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
93 % r. h. at 40 °C
EMC
EN 60947-5-3
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
EN 60947-5-2
Frequency
10,0 - 55,0 Hz
10,0 - 55,0 Hz
Amplitude
1,00 mm
1,00 mm
Shock stress
In accordance with the standard
EN 60947-5-2
EN 60947-5-2
Acceleration
30g
30g
Duration
18 ms
18 ms
Airgap creepage
Overvoltage category
III
III
Pollution degree
3
3
Rated insulation voltage
75 V
75 V
Rated impulse withstand voltage
0,80 kV
0,80 kV
Protection type
Housing
IP67
IP67
Mechanical data
541209
541210
Change of switching distance with
fluctions in temperature
+-0,01mm/°C
+-0,01mm/°C
Actuator 1
PSEN cs4.1
PSEN cs4.1
Typ. hysteresis
2,0 mm
2,0 mm
Operating distances
Assured operating distance Sao
8,0 mm
8,0 mm
Typical operating distance So
11,0 mm
11,0 mm
Assured release distance Sar
20,0 mm
20,0 mm
Typical release distance Sr
14,0 mm
14,0 mm
Min. distance between safety
switches
100 mm
100 mm