PSEN 4.2a/b/p/M12
Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02
13
Connection to PNOZmulti
Safety gate with switch type 3
I0, I1: Inputs OSSD
I2: Signal input
I2
I0
I1
grün
grau
gelb
Connection to PSS
Safety gate standard block SB64
I00, I01: OSSD inputs
I02: Signal input
grün
grau
gelb
Teaching in the actuator
The
first
actuator detected by the safety switch PSEN cs4.1 is automatically taught in as
soon as it is brought into the response range.
NOTICE
No other actuator may be taught in once this actuator has been taught.
Installation
}
The safety switch and actuator should be installed opposite each other in parallel.
CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.
}
Safety switches and actuators should only be secured using M4 screws with a flat head
(e.g. M4 cheese-head or pan head screws).
}
The actuator should be protected from unauthorised removal and from contamination.
Close the mounting holes using the seals provided.
}
Torque setting: Max. 0.8 Nm.
}
The distance between two safety switches must be maintained (see
Safety switches and actuators
}
Should not be exposed to heavy shock or vibration and
}
Should not be used as a limit stop.