background image

Overview

Operating Manual PNOZ mmc2p
1002103-EN-02

7

2.3

Front view

Power

Legend:

}

X2: Serial interface RS232

}

LED:
– Power

Содержание PNOZ mmc2p

Страница 1: ...PNOZ mmc2p Operating Manual 1002103 EN 02 Configurable compact control systems PNOZmulti Mini...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...ty and liability 9 3 3 3 Disposal 9 3 3 4 For your safety 9 Section 4 Function description 10 4 1 Functions 10 4 2 Block diagram 10 Section 5 Installation 11 5 1 General installation guidelines 11 5 2...

Страница 4: ...is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates prevent...

Страница 5: ...Introduction Operating Manual PNOZ mmc2p 1002103 EN 02 5 INFORMATION This gives advice on applications and provides information on special fea tures...

Страница 6: ...connection to a base unit from the configurable control systems PNOZmultiMini The product has the following features Can be configured in the PNOZmulti Configurator 1 serial interface RS232 Status in...

Страница 7: ...Overview Operating Manual PNOZ mmc2p 1002103 EN 02 7 2 3 Front view Power Legend X2 Serial interface RS232 LED Power...

Страница 8: ...d for safety related functions The following is deemed improper use in particular Any component technical or electrical modification to the product Use of the product outside the areas described in th...

Страница 9: ...d liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the g...

Страница 10: ...roduct PNOZ mmc2p has a serial interface RS232 interface to Download the project Read the diagnostic data Set virtual inputs for standard functions Read virtual outputs for standard functions Informat...

Страница 11: ...ed using a fixing element e g retaining bracket or end angle Push the unit upwards or downwards before lifting it from the mounting rail To comply with EMC requirements the mounting rail must have a l...

Страница 12: ...o the expansion module Install the expansion module in the position in which it is configured in the PNOZmulti Configurator The position of the expansion modules is defined in the PNOZmulti Configurat...

Страница 13: ...etected and activated by the base unit as soon as the communication module has been connected to the base unit USB interface on the base unit connected If the USB interface on the base unit is already...

Страница 14: ...chip card The LEDs POWER DIAG FAULT IFAULT and OFAULT will light up on the base unit The safety system PNOZmulti is ready for operation when the POWER and RUN LEDs on the base unit and the POWER LED o...

Страница 15: ...nce with the standard EN 60068 2 14 Temperature range 0 60 C Storage temperature In accordance with the standard EN 60068 2 1 2 Temperature range 25 70 C Climatic suitability In accordance with the st...

Страница 16: ...aded terminal screw terminal Conductor cross section with screw terminals 1 core flexible 0 50 1 50 mm 22 12 AWG 2 core with the same cross section flexible without crimp connectors or with TWIN crimp...

Страница 17: ...inals PNOZ mmc2p mml1p 1 pc Spring loaded terminals 1 pieces 783 538 Spring terminals PNOZ mmc2p mml1p 10 pcs Spring loaded terminals 10 pieces 783 539 Screw terminals PNOZ mmc2p mml1p 1 pc Screw term...

Страница 18: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...

Отзывы: