Intended use

The fieldbus module PNOZ m ES Powerlink is an expansion module of the configurable
control system PNOZmulti 2. It is used for communication between the configurable control
system PNOZmulti 2 and Ethernet POWERLINK. Ethernet POWERLINK is designed for
fast data exchange at field level. The expansion module PNOZ m ES Powerlink is a pass-
ive subscriber (Controlled Node) of the Ethernet POWERLINK. The basic communication
functions with Ethernet POWERLINK conform to the System Description published by the
POWERLINK User Group (EPSG). The central controller (Managing Node) reads input in-
formation from the slaves and writes output information to the slaves as part of each cycle.
As well as the cyclical transfer of usable data, the expansion module PNOZ m ES Power-
link can also be used for diagnostic and commissioning functions.

The expansion module may only be connected to a base unit from the PNOZmulti system
(please refer to the document "PNOZmulti System Expansion" for details of the base units
that can be connected).

The configurable small control systems PNOZmulti are used for the safety-related interrup-
tion of safety circuits and are designed for use in:

}

E-STOP equipment

}

Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1

The expansion module may not be used for safety-related functions.

The following is deemed improper use in particular:

}

Any component, technical or electrical modification to the product

}

Use of the product outside the areas described in this manual

}

Use of the product outside the technical details (see 

Technical details [

 19]

).

NOTICE

EMC-compliant electrical installation

The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.

3.2

System requirements

Please refer to the "Product Modifications PNOZmulti" document in the "Version overview"
section for details of which versions of the base unit and PNOZmulti Configurator can be
used for this product.

Содержание PNOZ m ES Powerlink

Страница 1: ...PNOZ m ES Powerlink Operating Manual 1003193 EN 05 Configurable control systems PNOZmulti 2...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...Disposal 9 3 3 4 For your safety 9 Section 4 Function description 10 4 1 Functions 10 4 2 Input and output data 10 4 3 Block diagram 11 Section 5 Installation 12 5 1 General installation guidelines 1...

Страница 4: ...ion that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicate...

Страница 5: ...Introduction Operating Manual PNOZ m ES Powerlink 1003193 EN 05 5 INFORMATION This gives advice on applications and provides information on special fea tures...

Страница 6: ...um cycle time for an application of 32 Byte Output and 32 Byte Input is 275 s The minimum cycle time is 500 s at the maximum PDO size of 254 Byte Input and 32 Byte Output The inputs and outputs in thi...

Страница 7: ...verview Operating Manual PNOZ m ES Powerlink 1003193 EN 05 7 2 3 Front view Legend X1 X2 Ethernet POWERLINK interfaces 0 V 24 V Supply connections Functional earth LED Power L A1 L A2 S E Status Error...

Страница 8: ...document PNOZmulti System Expansion for details of the base units that can be connected The configurable small control systems PNOZmulti are used for the safety related interrup tion of safety circui...

Страница 9: ...y and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed t...

Страница 10: ...he data is structured as follows Input area PNOZ m ES Powerlink The values for the virtual inputs are set as an output in the Managing Node and trans ferred to the PNOZmulti 2 Each input has a number...

Страница 11: ...Function description Operating Manual PNOZ m ES Powerlink 1003193 EN 05 11 4 3 Block diagram Interface to next module Data ST Ethernet POWERLINK Interface to previous module 24 V 0 V Module Supply...

Страница 12: ...secured using a fixing element e g retaining bracket or end angle Open the locking slide before lifting the unit from the mounting rail To comply with EMC requirements the mounting rail must have a l...

Страница 13: ...or to the expansion module Install the expansion module in the position in which it is configured in the PNOZmulti Configurator The position of the expansion modules is defined in the PNOZmulti Config...

Страница 14: ...shielded RJ45 connectors indus trial connectors 100BaseTX cable in accordance with the Ethernet standard min Category 5 Measures to protect against interference Ensure the requirements for the indust...

Страница 15: ...45 socket 8 pin PIN Standard 8 1 1 TD Transmit 2 TD Transmit 3 RD Receive 4 n c 5 n c 6 RD Receive 7 n c 8 n c n c Not connected 6 4 Download modified project to the PNOZmulti system As soon as an add...

Страница 16: ...mmissioning Operating Manual PNOZ m ES Powerlink 1003193 EN 05 16 6 5 Connection example Ethernet POWERLINK Managing Node Ethernet POWERLINK Slave 1 Ethernet POWERLINK Slave 2 Ethernet POWERLINK Slave...

Страница 17: ...ase unit The expansion module PNOZ m ES Powerlink is configured and started automatically 7 1 Messages Legend LED on LED flashes LED flashes briefly LED off LED Meaning Power Supply voltage is present...

Страница 18: ...hernet Frames accu mulation of collisions on the network etc Green The bus controller has not detected any communication with Ethernet POWERLINK If communication with Ethernet POWERLINK is detec ted t...

Страница 19: ...Power consumption 0 2 W Max power dissipation of module 1 5 W Status indicator LED Fieldbus interface Fieldbus interface Ethernet POWERLINK V2 Device type Controlled Node Transmission rates 100 MBit...

Страница 20: ...ieldbus and module voltage Type of potential isolation Functional insulation Rated surge voltage 500 V Mechanical data Mounting position Horizontal on top hat rail DIN rail Top hat rail 35 x 7 5 EN 50...

Страница 21: ...tails Operating Manual PNOZ m ES Powerlink 1003193 EN 05 21 Mechanical data Dimensions Height 101 4 mm Width 22 5 mm Depth 110 4 mm Weight 90 g Where standards are undated the 2013 10 latest editions...

Страница 22: ...Features Order No PNOZ mm0 xp connector left Jumper yellow black to connect the modules 10 piece 779 260 Connection terminals Product type Features Order no Spring terminals PNOZ mmcxp 1 pc Spring lo...

Страница 23: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Отзывы: