PSEN opII3F Series
Operating Manual PSEN opII3F Series
1003504-EN-01
35
Check ambient conditions and installation
}
Correct orientation and attachment
Check the seating of the mounting screw by applying pressure to edge of the safety
light grid. Neither the device status LED
of the transmitter nor that of the receiver
may illuminate.
}
Safety distance
The safety distance must comply with the requirements in
Maintaining the safety
distance [
15]
.
}
Circumvention of the protected field
The hazardous zone must be secured so that it is impossible to access by circumvent-
ing the protected field
}
Protected field perimeters
The protected field perimeters (see
Dimensions [
40]
) must completely secure the
hazardous area, making it inaccessible.
}
Response and stopping times must fulfil the requirements in
Maintaining the safety
distance [
15]
Ensure that the safety light grid's response time and the machine's stopping time fulfil
the requirements in
Maintaining the safety distance [
15]
.
}
No intense or flashing light sources in the vicinity
There may be no especially intense or flashing light sources in the vicinity of the safety
light grid.
}
Ambient conditions
Please observe the
environmental conditions [
16]
.
}
Use of deviating mirrors
Check all areas that are bounded by a deviating mirror.
Operation
Display elements
The safety light grid’s operating status is indicated with LEDs in the end caps of the con-
nection side of the receiver and on the transmitter.
Device status
Reception quality:
III: best quality
I: worst quality
OSSD status (protected field LED)
LED indicator on the receiver