PSEN opII3F Series
Operating Manual PSEN opII3F Series
1003504-EN-01
16
Resolution
The safety light grids may only be used for protected fields in which a detection capability of
14 mm is sufficient.
Protected field perimeters
During planning, ensure sufficient protected field height to secure the hazardous area.
The protected field perimeter is defined in
dimensions [
40]
.
Ambient conditions
}
Install the safety light grids in an environment that corresponds to the environmental
data provided in the
Technical details [
42]
.
}
Do not install the safety light grid near particularly intense and/or flashing light sources;
this applies to the receiver in particular.
}
The transmitter of one safety light grid must not interfere with the receiver of another
safety light grid.
}
The transmitters and receivers of two different safety light grids must not be synchron-
ised.
}
Avoid strong electromagnetic interference when operating the safety light grid.
}
When operating the safety light grid, avoid the development of smoke, mist, or dust that
would reduce the grid’s operating range.