19
VOLTAGE
POWER SUPPLY
The machine should be connected only to a power supply of the same voltage as indicated on the nameplate, and
can only be operated on single
-
phase AC supply.
EMERGENCY STOP
There is an Emergency Stop Button on the machine
. The power supply to the motor is cut off when the Emergen-
cy Stop Button is pushed. Always make sure the Emergency Stop Button is pressed or completely unplug the ma-
chine when the machine accessories (e.g. Cutter or Grinding Chains) are not inside the drain.
The machine has an operator presence control or
‘
OPC
’.
When the control is not held down, the machine stops.
The Mini Coating Pump can also be used with the Micro Miller, range 12m/39ft
PICOTE MINI MILLER 8/17
The Mini Miller
Note: can also be used with the Micro Miller
Please refer to the Mini Miller manual
for more information
General Description
Cable Rack
Frame
Flexible Shaft
Motor & Bevel Gear (not shown)
Emergency Stop Bottom (red)
Power Switch
Speed Control
Foot Pedal—Operator Presence Control
Hand Guard & Strain Relief/inside Hand
Guard (not seen in photo)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Intended Use
This machine is intended for the following uses:
1.
Coating pipes from DN32
-
200 / 1.
1
/
4
’’
-
8’’
2.
Cleaning sewers, drains and pipes by grinding.
(Picote Grinding Chains)
3.
Reinstating branches in sewers and drains by
drilling and grinding. (Picote Lateral Cutter)
Always follow the manufacture
’
s instructions when
installing and using the machine with accessories.
SIZE SHAFT RANGE ROTATING SPEED OUTPUT (kW) POWER SOURCE WEIGHT
752x519x389 8mm 17m 500
-
2900rpm 110V:1.1kW 110v or 230v 27kg
29.6x20x15.3
’’
1/3’’
55ft 230V:1.2kW 59.5lb
When is use, always lay the machine down horizontally on the floor as shown above. When not in use, some
non
-
hazardous Picote Flexible Shaft Lubricant might leak from the hand guard.
1
2
3
4
5
6
9
8
7