41
Description of the ERR
Description of the ERR
Description of the ERR
Description of the ERROR Register
OR Register
OR Register
OR Register
The following list contains a description of the individual bits of the ERROR register. A “1” as a bit
leads to a deactivation of the output current. Bits 0, 1, 7 and 17 are excluded of this directive.
The ERROR bits are cleared by disabling of the ENABLE pin.
Bit
Bit
Bit
Bit
Name
Name
Name
Name
Read/Write
Read/Write
Read/Write
Read/Write Meaning
Meaning
Meaning
Meaning
0
CRC_DEVDRV_FAIL
ro
A CRC error was detected in the PLB driver. The driver
cannot be used. This does not affect the device but
the PLB.
1
CRC_DEFAULT_FAIL
ro
A CRC error was detected in the default values. A re-
save of the values should correct this.
2
CRC_CONFIG_FAIL
ro
A CRC error was detected in the internal
configuration values. Please contact your distributor.
3
reserved
ro
4
CRC_FFWDCAL_FAIL
ro
A CRC error was detected in the internal calibration
values. Please contact your distributor.
5
OCUR_DETECTED
ro
The over current protection has disabled the output.
6
TEMP_OVERSTEPPED
ro
The internal temperature was beyond safe operating
limits.
7
TEMP_WARNING
ro
The internal temperature is 5°C before shutdown.
8
TEMP_HYSTERESE
ro
Device is cooling down. Temperature needs to drop
below (maximum – 10°)
9
PULS_TOO_LONG
ro
The supplied trigger pulse was too long.
10
VOLTAGE_5V_FAIL
ro
Internal supply voltage error.
11
VOLTAGE_12V_FAIL
ro
Internal supply voltage error.
12
VOLTAGE_IN_FAIL
ro
The supply voltage is too low or too high
13
FAILED_TO_LOAD_DEF
ro
The loading of the default failed. Normally this is
because of an pending CRC error.
14
I2C_EEPROM_FAIL
ro
Internal EEprom error. Please contact your distributor.
15
I2C_DAC_1_FAIL
ro
Internal DAC error. Please contact your distributor.
16
I2C_DAC_2_FAIL
ro
Internal DAC error. Please contact your distributor.
17
ENABLE_POWERON
ro
ENABLE and / or MASTER_ENABLE pin was high
during power-on.
18-31 reserved
ro