39
GETADCVCAP
GETADCVCAP
GETADCVCAP
GETADCVCAP
Returns the voltage of the capacitor bank. The value is measured in 0.1[V].
GETADCISOLL
GETADCISOLL
GETADCISOLL
GETADCISOLL
Returns the external set point current. If the ISOLL_EXT bit in the LSTAT register is set, this value is
used instead of the internal one. It is measured in [A].
GETADCPULSSAMPLES
GETADCPULSSAMPLES
GETADCPULSSAMPLES
GETADCPULSSAMPLES
Returns the number of samples taken by the LDP-QCW during the last pulse. Please see chapter
“pulse measurement” for more information.
GETADCPULSIDIODE
GETADCPULSIDIODE
GETADCPULSIDIODE
GETADCPULSIDIODE
This command takes the number of the desired sample and returns the appropriate measurement
value. It is measured in [A]. If an invalid sample number is given, ILGLPARAM will be send.
GETADCPULSUDIODE
GETADCPULSUDIODE
GETADCPULSUDIODE
GETADCPULSUDIODE
This command takes the number of the desired sample and returns the appropriate measurement
value. It is measured in 0.1[V]. If an invalid sample number is given, ILGLPARAM will be send.
GETADCPULSVCAP
GETADCPULSVCAP
GETADCPULSVCAP
GETADCPULSVCAP
This command takes the number of the desired sample and returns the appropriate measurement
value. It is measured in 0.1[V]. If an invalid sample number is given, ILGLPARAM will be send.
GETADCPULSI
GETADCPULSI
GETADCPULSI
GETADCPULSI
This command takes the number of the desired sample and returns the appropriate measurement
value. If an invalid sample number is given, ILGLPARAM will be send.
GETADCPULSP
GETADCPULSP
GETADCPULSP
GETADCPULSP
This command takes the number of the desired sample and returns the appropriate measurement
value. If an invalid sample number is given, ILGLPARAM will be send.