14
Recommended Operating Conditions
Supply voltages
Min.
Typ.
Max.
Unit
HV+
0
-
+55
V
+5 V
+4.75
+5.0
+5.2
V
Trigger input
Min.
Typ.
Max.
Unit
EN
Differential
input low
threshold
-30
-100
mV
EP
Differential
input high
threshold
-30
0
mV
Pulse width
1
2
100
µs
Repetition rate
-
-
100
kHz
Channel selection
Min.
Typ.
Max.
Unit
CHSEL0 / CHSEL1 /
CHSEL2 / CHSEL3
input logic high
+2.4
+3.15
-
V
CHSEL0 / CHSEL1 /
CHSEL2 / CHSEL3
input logic low
-
2.1
+1.35
V
Address transition time
-
-
1.0
MHz
Absolute maximum Ratings (destroying limits)
Supply voltages
Min.
Max.
Unit
HV+
0
+55
V
+5 V
0
+5.2
V
Trigger input
Min.
Max.
Unit
Trigger signal voltage,
unterminated
0
+3.3
V
Trigger Signal:
Note that the maximum ratings for both
pulse width and repetition rate depend
on the actual high voltage supply (HV). See section “Power Losses” for guidance.