Internal specific fan power
SVL
int
1197 [W/(m³/s)]
Thermal transmission
η
t_nwla
82,10% [-]
Enclosure sound power level
L
WA
64 [dB(A)]
0,944 [m³/s]
3400 [m³/h]
Nominal external pressure, ZUL
°p
s,ext ZUL
50 [Pa]
Nominal external pressure, ABL
°p
s,ext ABL
50 [Pa]
Internal specific fan power
SVL
int
470 [W/(m³/s)]
Thermal transmission
η
t_nwla
83,65% [-]
Enclosure sound power level
L
WA
60 [dB(A)]
0,597 [m³/s]
2150 [m³/h]
Nominal external pressure, ZUL
°p
s,ext ZUL
300 [Pa]
Nominal external pressure, ABL
°p
s,ext ABL
300 [Pa]
Internal specific fan power
SVL
int
180 [W/(m³/s)]
Thermal transmission
η
t_nwla
87,55% [-]
Enclosure sound power level
L
WA
70 [dB(A)]
0,250 [m³/s]
900 [m³/h]
Nominal external pressure, ZUL
°p
s,ext ZUL
847 [Pa]
Nominal external pressure, ABL
°p
s,ext ABL
847 [Pa]
Internal specific fan power
SVL
int
179 [W/(m³/s)]
Thermal transmission
η
t_nwla
87,55% [-]
Enclosure sound power level
L
WA
41 [dB(A)]
0,250 [m³/s]
900 [m³/h]
Nominal outside pressure ZUL
°p
s,ext ZUL
50 [Pa]
Nominal outside pressure ABL
°p
s,ext ABL
50 [Pa]
Filter class
Final pressure
di˜erence
G1-G4
150 Pa
M5-F7
200 Pa
F8 - F9
300 Pa
Nominal airfl w
q
nom
Nominal airfl w
q
nom
Nominal airfl w
q
nom
Nominal airfl w
q
nom
* Types of heat recovery:
none
Fluid circulation heat exchanger
other heat recovery system
The ventilation unit complies with Eco-design Directive (EU Regulation 1253/2014) as required for 2018.
Visual filter warning
The ventilation unit has a visual warning to replace the filter. An error message will be displayed on the control panel
when the set pressure di˝erence is exceeded.
WARNING: The plant will not work efficiently unless the filter is replaced regularly, causing power consumption to
increase.
Disposal
Equipment that is no longer functional must be uninstalled by a specialist firm and properly disposed of at a suitable
facility. The Electrical and Electronic Equipment Act (EAG-VO), implementing Community law Directives 202/95/EC
(RoHS) and 2002/96/EC (WEEE Directive) applies.
Point 2
Point 3
Point 4
Point 5
** The energy class is calculated based on the annual operating hours (8760 h) and average pressure loss (see table below for fin l
pressure loss pursuant to ÖNORM EN 13053).
Max. pressure drop across filter pursuant to ÖNORM EN 13053:
Information based on the current state of knowledge of EU Regulation 1253/2014
Download from: www.pichlerluft.at
O P E R A T I N G A N D I N S T A L L A T I O N I N S T R U C T I O N S L G