USER OPERATING INSTRUCTIONS - WOOD 

 
Please read the important notices given above before referring to the main instruction book for detailed 
operating instructions. 
 

HETAS Ltd Approval 

HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Ap-
proval does not cover the use of other fuels either alone or mixed with the recommended fuel, nor does it 
cover instructions for the use of other fuels. 
 

Recommended fuels 

Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the 
main stove manuals. 
 

Door operation 

The door handle may become hot during operation, use the tool to open and close the doors, if  appropriate. 

Lighting of fire 

Place some firelighters or paper and dry kindling wood on the grate and cover with a small amount of fuel. 
Set air controls to maximum and set light to firelighters or paper. Close the doors and allow fire to burn 
until fuel is well alight then load with more fuel and adjust air controls to the required level of heat output. 
Before relighting the fire clean the firebed of ash and clinker and empty the ashpan. 
 

Refuelling 

Keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill 
over the top of the front fire bars.  Take care that fuel does not project over the front fire bars or damage to 
the glass may be caused when the doors are closed 

 
Flueway cleaning 

It is important that the baffle plate and all the stove flueways are kept clean.  When burning smokeless 
fuels they should be cleaned at least monthly.  When burning other fuels they should be cleaned at least 
once a week, and more frequently if necessary. 
Remove any sooty deposits from the baffle plate until they fall off into the fire. 
More soot will be deposited on the baffle plate and in the flueways if the stove is run at low levels for long 
periods.  If this is the case then more frequent cleaning will be necessary. 
 

Cleaning and maintenance 

The instructions detailed in the section “Maintenance” in the instruction booklet should be followed. 
 

Spare Parts 

Spare parts can be obtained from Robeys Limited 01773 820 940 
 

Trouble shooting 

The instructions detailed in the relevant section in the instruction booklet should be followed together with 
the following additional items: 
 

1.  Fire Will Not Burn 

Check that: 
a)  the air inlet is not obstructed in any way, 
b)  that chimneys and flueways are clear, 
c)  that a suitable fuel is being used, 
d)  that there is an adequate air supply into the room, 
e)  that an extractor fan is not fitted in the same room as the fire. 

 

2.  Fire Blazing Out Of Control

 

Check that: 
a)  the doors are tightly closed, 
b)  the air control is turned down to the minimum setting, 
c)  the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash, 
d)  a suitable fuel is being used, 
e)  the door seals are in good condition.

 

Содержание E903

Страница 1: ...d Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E mail info robeys co uk Web Site www robeys co uk Riverside Goods Road Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E ma...

Страница 2: ...E903 2 July 2012...

Страница 3: ...tective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury STOVE PERFORMANCE In the UK the stove has been approved by HETAS...

Страница 4: ...ove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the sto...

Страница 5: ...tion within this area Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insul...

Страница 6: ...xpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to p...

Страница 7: ...as directed in the instructions Dampers left open Operation with the air controls or dampers open can cause excess smoke The appliance must not be operated with air controls or dampers left open exce...

Страница 8: ...fire bars or damage to the glass may be caused when the doors are closed Flueway cleaning It is important that the baffle plate and all the stove flueways are kept clean When burning smokeless fuels t...

Страница 9: ...E903 9 July 2012...

Страница 10: ...duct identification data 21 2 6 Dimensions e903K 22 2 7 Dimensions e903M 22 2 8 Dimensions e903S 22 3 0 USE 23 3 1 Fuel 23 3 2 Combustion air regulation 24 3 3 Lighting for the first time 24 3 4 Light...

Страница 11: ...E903 11 July 2012 N O T F O R U K U S E...

Страница 12: ...E903 12 July 2012...

Страница 13: ...E903 13 July 2012...

Страница 14: ...E903 14 July 2012 Fig 10 11 The illustration and table identify the minimum requirements as dictated by Building Regulations...

Страница 15: ...E903 15 July 2012...

Страница 16: ...E903 16 July 2012...

Страница 17: ...E903 17 July 2012 Minimum 45cm Minimum 45cm N O T F O R U K U S E N O T F O R U K U S E N O T F O R U K U S E...

Страница 18: ...E903 18 July 2012...

Страница 19: ...E903 19 July 2012 N O T F O R U K U S E...

Страница 20: ...E903 20 July 2012...

Страница 21: ...E903 21 July 2012...

Страница 22: ...E903 22 July 2012...

Страница 23: ...E903 23 July 2012...

Страница 24: ...E903 24 July 2012...

Страница 25: ...E903 25 July 2012...

Страница 26: ...E903 26 July 2012...

Страница 27: ...E903 27 July 2012...

Страница 28: ...E903 28 July 2012...

Страница 29: ...E903 29 July 2012...

Страница 30: ...E903 30 July 2012...

Страница 31: ...E903 31 July 2012...

Страница 32: ...E903 32 July 2012...

Страница 33: ...E903 33 July 2012 Riverside Goods Road Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E mail info robeys co uk Web Site www robeys co uk...

Отзывы: