Piazzetta E903 Скачать руководство пользователя страница 4

E903

                                                                          4                                                                    

July 2012

 

 

PREPARATORY WORK AND SAFETY CHECKS 

IMPORTANT WARNING

 

This stove must not be installed into a chimney that serves any other heating appliance. 
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove 
to emit fumes into the room. 
 

Chimney 

For the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate 
draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke     
problems into the room.  
 
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove 
to the top of the chimney should be satisfactory. Alternatively the calculation procedure given in EN 
13384-1 may be used as the basis for deciding whether a particular chimney design will provide   
sufficient draught. 
 

Please Note, this appliance has been tested by the manufacturers and works 

on a 3.5m straight flue. 

  

The outlet from the chimney should be above the roof of the building in accordance with the          
provisions of Building Regulations Approved Document J. 
 
If installation is into an existing chimney then it must be sound and have no cracks or other faults 
which might allow fumes into the house. Older properties, especially, may have chimney faults or the 
cross section may be too large i.e. more than 230 mm x 230 mm. Remedial action should be taken, if 
required, seeking expert advice, if necessary. If it is found necessary to line the chimney then a flue 
liner suitable for solid fuel must be used in accordance with Building Regulations Approved        
Document J. 
 
Any existing chimney must be clear of obstruction and have been swept clean immediately before 
installation of the stove. If the stove is fitted in place of an open fire then the chimney should be 
swept one month after installation to clear any soot falls which may have occurred due to the        
difference in combustion between the stove and the open fire. 
 
If there is no existing chimney then either a prefabricated block chimney in accordance with Building 
Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be 
used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building 
Regulations. 
 
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for 
using for the complete chimney. The chimney and connecting fluepipe must have a minimum        
diameter of 150 mm and its  dimension should be not less than the size of the outlet socket of the 
stove. 
 
Any bend in the chimney or connecting fluepipe should not exceed 45°.  90° bends should not be 
used. 
 
Combustible material should not be located where the heat dissipating through the walls of fireplaces 
or flues could ignite it. Therefore when installing the stove in the presence of combustible materials 
due account must be taken of the guidance on the separation of combustible material given in   
Building Regulations Approved Document J and also in these stove instructions. 
 
If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted. 
Fitting of a draught stabiliser will affect the requirement for the permanent air supply into the room in 
which the stove is fitted in accordance with Approved Document J (see also combustion air supply). 
 
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the 
chimney and connecting fluepipe where it is not intended for the chimney to be swept through the 
appliance, also to permit visual checks on the integrity of the flue when the appliance is serviced. 

 

Содержание E903

Страница 1: ...d Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E mail info robeys co uk Web Site www robeys co uk Riverside Goods Road Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E ma...

Страница 2: ...E903 2 July 2012...

Страница 3: ...tective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury STOVE PERFORMANCE In the UK the stove has been approved by HETAS...

Страница 4: ...ove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the sto...

Страница 5: ...tion within this area Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insul...

Страница 6: ...xpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to p...

Страница 7: ...as directed in the instructions Dampers left open Operation with the air controls or dampers open can cause excess smoke The appliance must not be operated with air controls or dampers left open exce...

Страница 8: ...fire bars or damage to the glass may be caused when the doors are closed Flueway cleaning It is important that the baffle plate and all the stove flueways are kept clean When burning smokeless fuels t...

Страница 9: ...E903 9 July 2012...

Страница 10: ...duct identification data 21 2 6 Dimensions e903K 22 2 7 Dimensions e903M 22 2 8 Dimensions e903S 22 3 0 USE 23 3 1 Fuel 23 3 2 Combustion air regulation 24 3 3 Lighting for the first time 24 3 4 Light...

Страница 11: ...E903 11 July 2012 N O T F O R U K U S E...

Страница 12: ...E903 12 July 2012...

Страница 13: ...E903 13 July 2012...

Страница 14: ...E903 14 July 2012 Fig 10 11 The illustration and table identify the minimum requirements as dictated by Building Regulations...

Страница 15: ...E903 15 July 2012...

Страница 16: ...E903 16 July 2012...

Страница 17: ...E903 17 July 2012 Minimum 45cm Minimum 45cm N O T F O R U K U S E N O T F O R U K U S E N O T F O R U K U S E...

Страница 18: ...E903 18 July 2012...

Страница 19: ...E903 19 July 2012 N O T F O R U K U S E...

Страница 20: ...E903 20 July 2012...

Страница 21: ...E903 21 July 2012...

Страница 22: ...E903 22 July 2012...

Страница 23: ...E903 23 July 2012...

Страница 24: ...E903 24 July 2012...

Страница 25: ...E903 25 July 2012...

Страница 26: ...E903 26 July 2012...

Страница 27: ...E903 27 July 2012...

Страница 28: ...E903 28 July 2012...

Страница 29: ...E903 29 July 2012...

Страница 30: ...E903 30 July 2012...

Страница 31: ...E903 31 July 2012...

Страница 32: ...E903 32 July 2012...

Страница 33: ...E903 33 July 2012 Riverside Goods Road Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E mail info robeys co uk Web Site www robeys co uk...

Отзывы: