1.13
HOOD GRILLE
The hood grille has the function of allowing air to pass from inside
the hood to the environment or vice versa if the Multifuoco system
is installed.
Warm air comes out of the hood grille with the natural convection
system and it is therefore necessary to maintain the safety distances
from flammable materials such as: flammable ceilings or walls,
ledges/beams, furniture, curtains, etc.. The hood grille must be
installed at least 50cm from the ceiling and with at least 30cm safety
distance to the sides.
For the hood grille size, see the
“TECHNICAL DATA”
paragraph.
A non-closable hood grille must be installed without
connecting it to the stove so that the warm air that has
stratified inside the lining wall can flow out.
With a ceiling over 3 metres high, a NON-CLOSABLE hood
grille must be installed on the hood lining at a height of 30cm
from the ceiling to allow the stratified air to flow out.
MIN. 30 CM
MIN. 30 CM
M
IN
.
3
0
C
M
F
L
A
M
M
A
B
L
E
M
A
T
E
R
IA
L
S
F
L
A
M
M
A
B
L
E
M
A
T
E
R
IA
L
S
CEILING IN FLAMMABLE MATERIAL
Fig. 23
DT2030271-00
DT2010178-00
1.14
WOOD MANTEL PROTECTION
Wooden finishes, e.g. wood mantels, may be mounted on the
surround.
Wood mantels must be:
- installed outside the heat radiation area;
- self-supporting;
- installed with 1cm air gap from the surround or from the heating
part (Fig. 24).
The expansion joint is in ceramic fibre, which has the
function of insulating the surround from the metal structure of
the stove.
1
c
m
F
ir
e
b
o
x
H
o
o
d
o
r
s
u
rr
o
u
n
d
1 cm
Surround
Expansion joint
Load-bearing axis
Wood
mantel
Fig. 24
DT2030272-00
1.1
NORMATIVE DI RIFERIMENTO
DT2010027-02
1.16
PREVENTION OF DOMESTIC FIRES
The product must be installed and used in compliance with the manufacturer’s instructions and European and national standards as well
as local regulations.
when a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.) See the paragraph “CONNECTION TO THE FLUEWAY”
- It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining,
flammable liquids, etc. be kept outside the heat radiation range of the stove and at a distance of at least 1m from the heating block.
- For other information, see the paragraph “
MINIMUM SAFETY DISTANCES
” and “
CONNECTION TO THE FLUEWAY
”.
- The flue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at
least twice during the seasonal period from the lighting of the stove and during its use. When the stove has not been used for some time
it is advisable to carry out the checks mentioned above. For further information, consult a chimneysweep.
- Only use recommended fuels (See paragraph “
FUEL
”).
- Ensure compliance with building regulations document J.
1.1
NORMATIVE DI RIFERIMENTO
DT2010179-01
1.15
ELECTRIC POWER SUPPLY
Make sure there is a power socket 230V 50Hz in the rear stove wall ready for installing the ventilation kit and a switch on the outside of the
cladding to be able to cut off the power supply during maintenance or when the appliance is not being used.
The installation must be earthed and fitted with a circuit breaker in accordance with current wiring regulations.
The installation of any electrical services during the installation of this appliance must be carried out by a registered competent electrician
and in accordance with the requirements of the latest issue of BS 7671.
When connected ensure that the power cable does not come into contact with hot parts.