4. Make sure that the contact resistance is <0.1
Ω
at 25 A at all connection points relevant for
attaching the protective earth conductor.
6.3
Building a Multi-Axis System
The V-417.216211E1 can be used in XY systems.
Designations in these instructions:
■
Lower positioner: Forms the basis of the multi-axis system, is attached to an underlying
surface
■
Upper positioner: Forms the upper axis of the multi-axis system, is attached to the lower
positioner rotated by 90°
Tools and Accessories
■
Hex key AF3
■
Hex key AF4
■
Hex key AF6
■
PH2 screwdriver
■
, depends on the travel range of the lower positioner.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the V-417.216211E1.
►
Pay attention to the
depth of the mounting and locating holes (p. 31)
V-417.216211E1.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
Building a Multi-Axis System
1. Attach the connector box for the additional drag chain to the connector box for the lower
V-417. The screws are integrated in the connector box of the additional drag chain and can
be reached through the openings on the outside.
2. Fix the holder for the additional drag chain to the drag chain holder of the lower V-417
with two M4×40 screws.
6 INSTALLATION
V417M0003EN
‒
11/19/2018
15