5 Installation
N-422 Linear Drive
MP116E
Version: 1.1.1
15
INFORMATION
If the N-422 becomes contaminated with dirt, oil, lubricant or condensation, the
dynamic force and the velocity of the drive will decrease.
If necessary, install the entire system in a case to protect it against
contamination.
Prevent condensation from forming on the N-422. If condensation has formed
on the N-422, let the drive dry before startup.
INFORMATION
When the N-422 is installed in a mechanical system that is to be operated in closed-
loop mode, you need an external position sensor such as a linear encoder (not in
the scope of delivery). Furthermore, the electronics must be able to read out and
process the signals of the external position sensor.
Observe the installation instructions of the manufacturer when installing the
position sensor.
Mount the position sensor as closely as possible to the intended motion.
Observe the input and output signals of the electronics used to operate the N-
422.
INFORMATION
The moving object is fastened to the coupling element of the N-422.