NOTICE
Heating up of the drive during operation!
The heat produced during operation of the drive can affect your application.
Install the drive so that the application is not affected by the dissipated heat.
Ensure sufficient ventilation at the place of installation.
Make sure that the complete drive is underneath in contact with the surface on which the
drive is fixed.
NOTICE
Damage due to collisions!
Collisions can damage the drive, the load to be moved, and the surroundings.
Make sure that no collisions are possible between the drive, the load to be moved, and the
surroundings in the motion range of the drive.
Do
not
place any objects in areas where they can be caught by moving parts.
INFORMATION
For the positive direction of motion of the runner, see "Product View" (p. 7).
Connecting the N-331 to a Protective Earth Conductor
INFORMATION
Pay attention to the applicable standards for mounting the protective earth conductor.
The drive features a separate protective earth connection, see “Dimensions” on p. 24.
Figure 7: Example of a protective earth connection
Tools and accessories
Suitable protective earth conductor: Cross-
sectional area of the cable ≥0.75 mm
2
Suitable screwdriver
M4 screw for connecting the protective earth conductor