5 Installation
18
Version: 1.2
MP106E
M-235 Linear Actuators
NOTICE
Heating up of the M-235 during operation!
The heat produced during operation of the M-235 can affect your application.
Install the M-235 so that your application is not affected by the dissipating heat.
INFORMATION
Linear actuators with DC gear motors are equipped with integrated signal drivers for
cable lengths of
≤
10 m between linear actuator and motor controller.
5.2 Changing the Tip
INFORMATION
The supplied end pieces make it possible to realize different mechanical connections
to a load:
A flat end piece allows a wide-area connection to a load.
A spherical end piece allows a punctiform connection to a load.
To achieve optimum repeatability:
Use an end piece.
Make sure that the selected end piece is completely screwed in and does not have
any backlash.