![PI M-126 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/pi/m-126/m-126_user-manual_1554382030.webp)
6 Startup
26
Version: 3.0.0
MP42E
M-126 Precision Microtranslation Stage
Limit switches
M-126.PD1 / M-126.PD2
Unit
Logic
Open collector with pull-up to 5 V
Position
Negative limit switch position on the connector
side, reference edge in the middle of the travel
range, positive limit switch position opposite the
negative limit switch
Operating parameters for the M-126 with 2-phase stepper motor
Positioner
M-126.2S1
Unit
Drive screw pitch
0.5
mm
Motor
M-126.2S1
Unit
Nominal voltage
24
V DC
Nominal current, RMS
0.85
A
Resistance per phase
6.6 ±15 %
Ω
Inductance per phase
20.8 ±20 %
mH
Full step angle
0.9
°
Number of full steps per
revolution
400
Holding torque
0.305
Nm
Limit switches
M-126.2S1
Unit
Supply voltage
5
V
Current consumption
80
mA
Logic
Open collector with pull-up to 5 V
Position
Negative limit switch position on the connector
side, reference edge in the middle of the travel
range, positive limit switch position opposite the
negative limit switch
Содержание M-126
Страница 8: ......
Страница 18: ......
Страница 20: ......
Страница 36: ......
Страница 42: ...10 Technical Data 38 Version 3 0 0 MP42E M 126 Precision Microtranslation Stage M 126 DG1...
Страница 43: ...10 Technical Data M 126 Precision Microtranslation Stage MP42E Version 3 0 0 39 M 126 PDx...
Страница 44: ...10 Technical Data 40 Version 3 0 0 MP42E M 126 Precision Microtranslation Stage M 126 2S1...
Страница 45: ...10 Technical Data M 126 Precision Microtranslation Stage MP42E Version 3 0 0 41 M 126 M0...
Страница 47: ...10 Technical Data M 126 Precision Microtranslation Stage MP42E Version 3 0 0 43 M 125 90 adapter bracket...
Страница 52: ......