Area of application
For indoor use only
Maximum altitude
2000 m above msl
Relative humidity
Max. 80 % for temperatures to 31 °C,
linearly decreasing to 50 % at 40 °C; not con-
densing
Storage temperature
-25 °C to 55 °C
Transport temperature
-25 °C to 70 °C
Overvoltage category
II
Supply voltage fluctuations
Max. ±10 % of the nominal voltage
Protection class
I
Degree of pollution
2
Degree of protection according to IEC 60529 IP10
12.4
Dimensions
A
D
A+D
F
(Energychain
overlap at
hardstop)
X
B
center of travel position
(reference position)
20
6,6/
11,2x8
1/2 LSW (LE1)
1/2 HDS
1/2 HDS
1/2 LSW (LE2)
150
1
5
0
4 x
4 H7x7/10
8
,5
7
,5
8
3
,5
8
2
,5
C
X
166
7
0
E
E
D1
F
L-417
.xxxx
11E1
L-417.
xxxx
25E1
D2
L-417
.xxxxxx
BASIS
MODELL
TRAVEL
NOMINAL
LIMITSWITCH TO
LIMITSWITCH
LSW
HARDSTOP
TO
HARDSTOP
HDS
A
B
C
D
E
F
D1
D2
L-417.xxx211E1x L-417.xxx025E1x
L-417.xxxxxxE1 L-417.xxxxxxE1B
L-417.xxxx11E1x
L-417.xxx2xx
L-417.xxx0xx
L-417.xxxxxx
L-417.xxxxxxB
L-417.xxxx25E1x
L-417.05xxxx
102 (4")
102 - 105
-
109
365
185
150
119,5
153,5
28
67
L-417.09xxxx
204 (8")
204 - 207
-
214
470 237,5
150, 350
119,5
153,5
28
71
L-417.13xxxx
305 (12")
305 - 308
-
314
570 287,5
150, 350
119,5
153,5
28
66
L-417.17xxxx
407 (16")
407 - 410
-
419
675
340
150, 350, 550
119,5
153,5
28
69
L-417.21xxxx
508 (20")
508 - 511
-
519
775
390
150, 350, 550
119,5
153,5
28
65
L-417.25xxxx
610 (24")
610 - 613
-
619
875
440
150, 350, 550, 750
119,5
153,5
28
69
L-417.33xxxx
813 (32")
813 - 816
-
824
1080 542,5 150, 350, 550, 750, 950
119,5
153,5
28
68
Figure 11: Dimensions of the L-417.xx9025E1
Dimensions in mm. Note that the decimal places are separated by a comma in the drawings.
12 TECHNICAL DATA
L417UM0002EN
‒
10/25/2022
34