5 Installation
16
Version: 1.2.0
MP164E
L-402 Mniature Stage
Figure 8: Mounting of the protective earth conductor (profile view)
1
Base body of the L-402
2
Flat washer
3
Safety washer
4
Screw
5
Cable lug
6
Protective earth conductor
Requirements
You have read and understood the general notes on installation (p. 11).
Tools and accessories
Suitable protective earth conductor: Cable cross section ≥ 0.75 mm
2
Screw, M4x8, ISO 7045
2 washers, ISO 7089-4
2 safety washers, S4
Suitable screwdriver
Connecting the L-402 to the protective earth conductor
1.
If necessary, attach a suitable cable lug to the protective earth conductor.
2.
Affix the cable lug of the protective earth conductor using the M4 screw on the
protective earth connection of the L-402 as shown in the profile view.
3.
Tighten the M4 screw with a torque of 1.2 Nm to 1.5 Nm.
4.
Make sure that the contact resistance at all connection points relevant for mounting
the protective earth conductor is <0.1 Ω at 25 A.