6 Installation
C-863 Mercury Controller
MS205Equ
Version: 2.0.0
37
6.6.2 Connecting to the USB Interface
NOTICE
Incorrect wiring!
Connecting the USB and RS-232 interfaces of the controller to the PC at the same
time can damage the PC or the controller.
Connect either the USB or the RS-232 interface to the PC.
Prerequisites
The PC has a free USB interface.
Tools and accessories
USB cable (type A to Mini-B) for connecting to the PC (order number
000014651; included in the scope of delivery)
Connecting the C-863 to the PC
Connect the USB socket of the C-863 and the USB interface of the PC with
the USB cable.
6.6.3 Setting Up a Daisy Chain Network
INFORMATION
Interlinking in a daisy chain occurs in series. See also "Definition" (p. 3). Here the
first controller is connected directly to the PC.
INFORMATION
The DIP switches of the C-863 must be set accordingly:
Set a unique address for each controller in a daisy chain network. In doing so,
one of the controllers must have the address 1. This controller does not have to
be the one directly connected to the PC. Details see "Controller Address" (p. 43).
Set the same baud rate for every controller in a daisy chain network. Details see
"Baud Rate" (p. 44).