background image

 

 

 

 

 

 

www.phywe.com, © All rights reserved 

 

12999-99 / 1321

 

 

 
Then  select  a  search  provider  that  you  want  to  use  in  the 
browser as well as on the home screen. 
 

 

 
Activate  the  display  lock  to  prevent  unauthorised  access  to 
the  tablet. 

Caution: 

a  display  lock  is  for  your  own  security 

and should always be activated. 
 
  

 

 
If you allow Google Voice Match to accept voice commands 
and  forward  them  to  Assistant  devices  such  as  the  tablet, 
you can agree to this below, otherwise click "Skip". 
 
 

 

 
At the end of the initial setup, you have the option of making 
further  adjustments  and  settings.  However,  you  can  also 
make these settings at a later time 
 
 

5.2.3    Switch off the device. 

Press  the  switch-on  button  for  longer  than  3s.  Now  you  will 
see  a selection  window  on  the  right-hand  side  for switching 
off the unit or restarting the device. 
If you press the power button only briefly, you only switch off 
the display. 

 
5.3 Using Android 

The  following  section  deals  with  the  basic  use  and  settings 
of  Android.  Due  to  the  large  number  of  settings  and  com-
mands, only  the  areas  that  ensure smooth  use  of  the  PHY-
WE apps are described here. For further information on An-
droid,  various  instructions  are  available  on  the  Internet,  or 
use our video descriptions at  
www.youtube.com/c/phywesysteme. 
 

5.3.1 The start screen 

 

 

 
Information line top left and top right: 
 

 

 
Time        Messages      Network      Battery status 
 
Navigation elements below: 
 
 
 

 

Back      Google Assistant        Quit 
     

Содержание Cobra SMARTlink

Страница 1: ...ssary to avoid damage to it as well as for user safety Use the unit only for its intended purpose Protect the device from dust moisture and vapours Clean the unit with a slightly damp lint free cloth Sharp cleaning agents or solvents are unsuitable Make sure that no liquid enters the housing openings Do not open the device The voltage measurement input of the unit is intended for signals in the ra...

Страница 2: ...led in current EC guidelines The characteristics of this product qualify it for the CE mark This device is only to be put into operation under specialist supervision in a controlled electromagnetic environment in research educational and training facilities schools univer sities institutes and laboratories The individual connected lines must not be longer than 2m Electrostatic charges or similar e...

Страница 3: ...he Start button to pro ceed with the initial setup Select the appropriate Wi Fi network to which you want to connect the tablet If you click the Set up offline option some Google services cannot be set up If content is to be transferred from a previously used device the Next button must be pressed here otherwise please select Do not copy If you have a Google account you can now sign in to Google P...

Страница 4: ... at a later time 5 2 3 Switch off the device Press the switch on button for longer than 3s Now you will see a selection window on the right hand side for switching off the unit or restarting the device If you press the power button only briefly you only switch off the display 5 3 Using Android The following section deals with the basic use and settings of Android Due to the large number of setting...

Страница 5: ...he Apps This is necessary so that connected Cobra SMARTsense sensors or Cobra DigiCart can communicate via Bluetooth Low Energy Please confirm the release If location sharing is rejected neither Cobra SMARTsense sensors nor DigiCart can be de tected At measureAPP all connected sensors as well as the in ternal sensors are displayed on the left under Devices If you want to use the internal SMARTlink...

Страница 6: ...e scope of delivery here Make sure the polarity is correct the negative pole is wider See picture above 5 4 5 Voltage 30V Measure the voltage using the 4mm test leads included in the delivery The exemplary connection of a voltage source with load is shown above Do not measure voltage above 30V or below 30V This can lead to the destruction of the measuring electronics 5 4 6 Current 1A Measure the c...

Страница 7: ...WxH 277 x 175 x 25 mm Weight full scale 830 g 7 SCOPE OF DELIVERY The scope of delivery includes Cobra SMARTlink 12999 99 USB connection cable type C USB charging adapter 5V 2A 2x NiCrNi temperature sensor type K 2x connection cable red 4mm l 50cm 1x connection cable blue 4mm l 50cm Operating instructions 8 ACCESSORIES The following accessories are available USB connection cable type C07935 00 Sof...

Отзывы: