phytron
11
MA 1311-A001 EN
4.3 Features
Features
Main controller
Modular controller
phyMOTION
TM
Power supply
- 24 V
DC
internal via central entry point from the
POWM module
- 24+1 V
DC
external directly to the PIDM01 module
- 5 V
DC
internal
Current consumption
(max.)
24 V
DC
supply:
- internal: 2 A for the complete PIDM01 module if it is
supplied via the central entry point for the POWM
- external: 4 A for the complete PIDM01 module if it is
supplied directly to the PIDM01 module
5 V
DC
internal:
- 30 mA per temperature module
- 10 mA (24 V
DC
I/O)
Cable length
– digital
inputs
30 m
if longer (100 m max.) use shielded cable and contact shield
close to the controller.
Status LEDs
see chap. 7
Interfaces
4 digital inputs
I1 to I4
Input level: 24 V
DC
Switching threshold: about. 2.4 V
DC
Electrical isolation via optocoupler
Switching frequency max.: 50 kHz
Protected against over voltage up to 35 V
DC
Analogue measuring
inputs
Temperature evaluation
- thermocouple type K (needs sub module: KTS01)
- PT100 sensor (needs sub module: PTS01)