![phytron phyMOTION INAM01.1 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/phytron/phymotion-inam01-1/phymotion-inam01-1_translation-of-the-original-manual_1554207027.webp)
phytron
27
MA 1275-A004 EN
5.2.5 Option: Encoder Connection X1
Fig. 8: Pin assignment of the encoder
•
Suitable encoder types depend on the selected evaluation module (ECES01/ECAS01):
– differential incremental encoder with quadrature signals (ECAS01/ECES01)
– Absolute encoder according to the SSI standard (ECAS01/ECES01)
– EnDat encoder (ECES01)
•
The incremental encoder supply voltage (5 or 5.5 V
DC
/ 200 mA max.) is generated by the
controller.
•
Use shielded cables, twisted pair, for encoder connection. The transmission mode includes no
protection against faulty transmission values.
•
Wiring diagrams for the encoder types: see next page.
i
CAUTION – Possible damage!
Damage of the module by wrong connection..
- Do not exchange the 10 pin connector for limit switches with the
10 pin connector for the encoder evaluation. Module and encoder can be
damaged.
- Also ensure that the encoder is configured correctly in its programming. The
connection of an incremental encoder and parameterising for SSI can cause
damage.
Содержание phyMOTION INAM01.1
Страница 10: ...Manual INAM01 INAM02 MA 1275 A004 EN 10...
Страница 11: ...phytron 11 MA 1275 A004 EN 4 2 Declaration of Conformity Modules with Internal Supply INT...
Страница 12: ...Manual INAM01 INAM02 MA 1275 A004 EN 12...
Страница 25: ...phytron 25 MA 1275 A004 EN Fig 5 PE connection for 5 wire motor cable by the NETM01 module...
Страница 33: ...phytron 33 MA 1275 A004 EN 5 6 wire LVDT Fig 5 5 wire LVDT RVDT wiring Fig 6 6 wire LVDT RVDT wiring...
Страница 34: ...Manual INAM01 INAM02 MA 1275 A004 EN 34...
Страница 35: ...phytron 35 MA 1275 A004 EN Synchronisation Fig 7 Synchronisation wiring...
Страница 37: ...phytron 37 MA 1275 A004 EN Fig 9 Sample form...