Stepper motors with 8 leads can be connected with the windings wired in parallel (1) or series (2).
For 6 lead stepper motors, wiring scheme (3) with series windings is recommended.
If wiring scheme (3) cannot be used because of the motor construction, the motor may be operated
with only two of the four windings energized according to wiring scheme (4).
i
CAUTION – Possible damage!
Destruction of the power stage by connecting a 5 phase stepper motor.
- Do not connect any 5 phase stepper motors to avoid damage.
Motor time constant
τ:
R
L
=
τ
applies to the electrical motor time constant
τ.
The total inductance L
total
is equal to the winding inductance in a parallel circuit,
because of interlinked inductances.
L
total
=
4 x L applies to a series circuit.
The result is an equal motor time constant
τ
for a serial and a parallel circuit:
Circuit
series
parallel
Resistance R
total
2 x R
2
R
Inductance L
total
4 x L
L
Motor time constant
τ
R
L
x
2
R
x
2
L
x
4
series
=
=
τ
R
L
x
2
R/2
L
=
τ
parallel
=
Содержание phyMOTION INAM01.1
Страница 10: ...Manual INAM01 INAM02 MA 1275 A004 EN 10...
Страница 11: ...phytron 11 MA 1275 A004 EN 4 2 Declaration of Conformity Modules with Internal Supply INT...
Страница 12: ...Manual INAM01 INAM02 MA 1275 A004 EN 12...
Страница 25: ...phytron 25 MA 1275 A004 EN Fig 5 PE connection for 5 wire motor cable by the NETM01 module...
Страница 33: ...phytron 33 MA 1275 A004 EN 5 6 wire LVDT Fig 5 5 wire LVDT RVDT wiring Fig 6 6 wire LVDT RVDT wiring...
Страница 34: ...Manual INAM01 INAM02 MA 1275 A004 EN 34...
Страница 35: ...phytron 35 MA 1275 A004 EN Synchronisation Fig 7 Synchronisation wiring...
Страница 37: ...phytron 37 MA 1275 A004 EN Fig 9 Sample form...