Manual MSX
+
MA 2128-A004 EN
44
F?
FH?
Read MSX
+
status in decimal mode
Read MSX
+
status in hexadecimal mode
e. g. f1
e. g. f01
(= Error undervoltage/
overvoltage)
G?
G1 or G0
Read preferential direction
Set preferential direction
g0 or g1
g1 or g0
M0...M12
M?
Set step width
Read step width
m0...m12
m0...m12
PN?
PNAxis7
PN/
Read the axis name
Store the axis name
Delete the axis name
pn<String> (e.g. axis 4)
pnAchse7
pn0
Q?
Error inquiry
q0...q3
R?
R450
Read run current
Set run current to 4.5 A
r.m.s.
e.g. r480 (= 4.8 A
r.m.s.
)
r450
S?
S270
Read stop current
Set stop current to 2.7 A
r.m.s.
e.g. s18 (= 1.8 A
r.m.s.
)
s270
U?
U0 or U1
Read deactivation of the power stage
Set deactivation of the power stage
e. g. u0 or u1
u0 or u1
W
Write EPROM
w1
Z+, Z-
Do the motor self-test
z1
Remark:
pn0 is also the answer of PN?, if no name is saved.