Manual MSX
+
MA 2128-A004 EN
42
Instruction
code
Parameter
name
Type Value
Description
De-
fault
values
M
Step width
R/W
0 to 15
0= 1/1
1= 1/2 with TC
1)
and CS
2)
2= 1/4 with CS
3= 1/5 with CS
4= 1/10 with CS
5= 1/20 with CS
6= 1/2 with TC
7= 1/4 without CS
8= 1/5 without CS
9= 1/10 without CS
10= 1/20 without CS
11= 1/4 with CS and BLOW UP
3)
12= 1/5 with CS and BLOW UP
13= 1/10 with CS and BLOW UP
14= 1/20 with CS and BLOW UP
15= 1/2
3
PN
Axis name
R/W
<String>
max.40
characters
Assign or read an axis name
into the EPROM
–
Q
Error inquiry R
0 to 3
0=no error
1=undervoltage/overvoltage
2=overtemperature
3=overcurrent
4=deactivated
–
R
Run current
R/W
0 to 1100
Run current values from
0 to 11 A
r.m.s
0
S
Stop current R/W
0 to 1100
Stop current values from
0 to 11 A
r.m.s
0
U
4
Power stage
deactivation
R/W
0 or 1
0 = activated
1 = deactivated
1
W
Write
EPROM
X
–
Write parameter into EPROM
–
1)
TC= with torque compensation (see chap 14.1)
2)
CS=Current Shaping (see chap. 14.3.)
3)
BLOW UP: see chap. 14.4.
4)
Remark for ServiceBus mode: Please deactivate the power stage only by U=0, if it isn’t still deactivated by
the input
Activation
.
Содержание MSX+ 152/120 48F SBM-485
Страница 14: ...phytron 13 MA 2128 A004 EN 4 Technical Data 4 1 Declaration of Incorporation ...
Страница 32: ...phytron 31 MA 2128 A004 EN 8 2 Wiring Schemes Connection diagrams for 4 6 and 8 lead stepper motors ...
Страница 34: ...phytron 33 MA 2128 A004 EN 8 4 VG Connector 48 pin male multipoint connector acc to DIN 41612 version F ...
Страница 65: ...Manual MSX MA 2128 A004 EN 64 W Warranty 52 Winding inductance 29 Winding resistance 29 Wiring scheme 29 ...
Страница 66: ...Phytron GmbH Industriestraße 12 82194 Gröbenzell T 49 8142 503 0 F 49 8142 503 190 www phytron eu ...