7.6.1
UART3 Routing (RN47)
RN47 is used to route the signals of UART3 serial interface through the RS-232
transceiver or around the RS-232 transceiver when not populated. When RN47 is not
populated RXD3_TTL,TXD3_TTL,RTS3_TTL and CTS3_TTL are routed through the RS-
232 transceiver U21 and come out as x_RXD3_RS232, x_TXD3_RS232,
x_RTS3_RS232 and x_CTS3_RS232 at the phyCORE-connector pins X1 pin 22D, X1
pin 23D, X1 pin 25D, X1 pin 26D. If U21 does not populate the module, RN47 is
populated to route the TTL level signals to these same pins.
The standard phyCORE-i.MX31 module will have U21 populated, thereby routing the RS-
232 level signals to the phyCORE-connector. Be sure the phyCORE-i.MX31 configuration
you are working with before interfacing these signals outside of the module as incorrect
voltage levels will likely cause damage to on-board and off-board components.
The following configurations are possible:
Table 11: RN47 UART3 signal routing
S
IGNAL
C
ONFIGURATION
RN47
x_RXD3_RS232, x_TX3_RS232, x_ RTS3_RS232, x_
CTS3_RS232 as RS-232 level signals at X1 pin 22D, X1 pin
23D, X1 pin 47D and X1 pin 46D
not populated
x_RXD3_RS232, x_TX3_RS232, x_ RTS3_RS232, x_
CTS3_RS232 as TTL level signals at X1 pin 22D, X1 pin
23D, X1 pin 47D and X1 pin 46D
populated
1 Defaults are in
bold blue
text
Содержание phyCORE-i.MX31
Страница 1: ...phyCORE i MX31 HARDWARE MANUAL EDITION JULY 2007 A product of a PHYTEC Technology Holding company...
Страница 9: ...Contents PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 10: ......
Страница 32: ...phyCOREi MX31 J20 J18 J19 J16 J17 Figure 6 Jumper locations top view 22 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 55: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 45...
Страница 57: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 47...
Страница 86: ...phyCOREi MX31 On NOR Flash On NAND Flash 76 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 90: ...phyCOREi MX31 80 PHYTEC Messtechnik GmbH 2007 L 700e_0 JP17 more info JP604 more info...
Страница 109: ...The phyCORE i MX on the Development Board PHYTEC Messtechnik GmbH 2007 L 700e_0 99 15A x_TRIGGER Trigger 15B GND Ground...
Страница 128: ...phyCOREi MX31 118 PHYTEC Messtechnik GmbH 2007 L 700e_0 13 6 1 LCD 004 Physical Dimensions TBD...
Страница 135: ...Published by PHYTEC Messtechnik GmbH 2007 Ordering No L 700e_0 Printed in Germany...