The jumpers (J = solder jumper) have the following functions:
Table 2:
Jumper settings
D
EFAULT
S
ETTING
A
LTERNATIVE
S
ETTING
S
EE
S
ECTION
J1
2 + 3
Selects x8 organization of
Ethernet EEPROM U4
1 + 2
Selects x16 organization of
Ethernet EEPROM U4
J2
2 + 3
Thermal Sensor U16 address
bit A1 connected to VCC
1 + 2
Thermal Sensor U16
address bit A1 connected to
GND
J3
2 + 3
Thermal Sensor U16 address
bit A2 connected to GND
1 + 2
Thermal Sensor U16
address bit A2 connected to
VCC
N/A
J4
2 + 3
EEPROM U17 address bit A0
connected to GND
1 + 2
EEPROM U17 address bit
A0 connected to VCC
J5
2 + 3
EEPROM U17 address bit A1
connected to VCC
1 + 2
EEPROM U17 address bit
A1 connected to GND
J6
2 + 3
EEPROM U17 address bit A2
connected to GND
1 + 2
EEPROM U17 address bit
A2 connected to VCC
J8
closed
EEPROM U17 is not write
protected
closed
EEPROM U17 is write
protected
J7
open
RAM-Bank input is high.
(only DDR-RAM bank 0 is
populated)
closed
RAM-Bank input is low.
(DDR-RAM bank’s 0 & 1 are
populated)
J9
open
WDRESET output from i.MX31
is not connected to WDI input
of MC13783; watchdog is
disabled
closed
WDRESET output from
i.MX31 is connected to WDI
input of MC13783; watchdog
is enabled
N/A
J10
open
Power up Mode select
(PUMS1) is floating
closed
Power up Mode select
(PUMS1) is connected to
VATLAS (high)
J11
open
Power up Mode select
(PUMS1) is floating
closed
Power up Mode select
(PUMS1) is connected to
GND (low)
J12
open
Power up Mode select
(PUMS2) is floating
closed
Power up Mode select
(PUMS2) is connected to
VATLAS (high)
J13
closed
Power up Mode select
(PUMS2) is connected to GND
(low)
open
Power up Mode select
(PUMS2) is floating
J14
open
Power up Mode select
(PUMS3) is floating
closed
Power up Mode select
(PUMS3) is connected to
VATLAS (high)
J15
open
Power up Mode select
(PUMS3) is floating
closed
Power up Mode select
(PUMS3) is connected to
GND (low)
Содержание phyCORE-i.MX31
Страница 1: ...phyCORE i MX31 HARDWARE MANUAL EDITION JULY 2007 A product of a PHYTEC Technology Holding company...
Страница 9: ...Contents PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 10: ......
Страница 32: ...phyCOREi MX31 J20 J18 J19 J16 J17 Figure 6 Jumper locations top view 22 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 55: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 45...
Страница 57: ...Debug Interface X201 PHYTEC Messtechnik GmbH 2007 L 700e_0 47...
Страница 86: ...phyCOREi MX31 On NOR Flash On NAND Flash 76 PHYTEC Messtechnik GmbH 2007 L 700e_0...
Страница 90: ...phyCOREi MX31 80 PHYTEC Messtechnik GmbH 2007 L 700e_0 JP17 more info JP604 more info...
Страница 109: ...The phyCORE i MX on the Development Board PHYTEC Messtechnik GmbH 2007 L 700e_0 99 15A x_TRIGGER Trigger 15B GND Ground...
Страница 128: ...phyCOREi MX31 118 PHYTEC Messtechnik GmbH 2007 L 700e_0 13 6 1 LCD 004 Physical Dimensions TBD...
Страница 135: ...Published by PHYTEC Messtechnik GmbH 2007 Ordering No L 700e_0 Printed in Germany...