background image

  

Preface 

This  phyBOARD-WEGA-AM335x  Board Hardware Manual describes the System on Module's design 
and functions. Precise specifications for the TI AM335x processor can be found in the processor datasheet 
and/or user’s manual.

In this hardware manual and in the schematics, active low signals are denoted by a "/" preceding the signal 
name, for example: /RD. A "0" represents logic-zero or low-level signal, while a "1" represents a logic one 
or high-level signal. 

Declaration of Electro Magnetic Conformity of the phyBOARD-WEGA-AM335x

PHYTEC System on Modules (SOMs) are designed for installation in electrical appliances or, combined 
with the PHYTEC Carrier Board, can be used as dedicated Evaluation Boards (for use as a test and 
prototype platform for hardware/software development) in laboratory environments. 

CAUTION: 

PHYTEC products lacking protective enclosures are subject to damage by ESD and, 
hence,   may   only   be   unpacked,   handled   or   operated   in   environments   in   which 
sufficient precautionary measures have been taken in respect to ESD-dangers. It is 
also   necessary   that   only   appropriately   trained   personnel   (such   as   electricians, 
technicians and engineers) handle and/or operate these products. Moreover, PHYTEC 
products should not be operated without protection circuitry if connections to the 
product's pin header rows are longer than 3 mm. 

PHYTEC products fulfil the norms of the European Union's Directive for Electro Magnetic Conformity 
only in accordance to the descriptions and rules of usage indicated in this hardware manual (particularly in 
respect to the pin header row connectors, power connector and serial interface to a host-PC). 

Implementation   of   PHYTEC   products   into   target   devices,   as   well   as   user 
modifications   and   extensions   of   PHYTEC   products,   is   subject   to   renewed 
establishment   of  conformity   to,   and  certification   of,  Electro   Magnetic   Directives. 
Users should ensure conformance following any modifications to the products as well 
as implementation of the products into target systems. 

The phyBOARD-WEGA-AM335x Board is one of a series of PHYTEC System on Modules that can be 
populated with different controllers and, hence, offers various functions and configurations. PHYTEC 
supports a variety of 8/16 and 32-bit controllers in two ways: 

1. As the basis for Rapid Development Kits which serve as a reference and Evaluation platform. 
2. As insert-ready, fully functional phyCORE OEM modules, which can be

Embedded  directly into the user's peripheral hardware design. 

© PHYTEC Embedded Pvt. Ltd. 2014                                                                                               6 

Содержание phyBOARD WEGA-AM335x

Страница 1: ...phyBOARD WEGA AM335x Single Board Computer Hardware Manual Product No PCL 051 PBA CD 02 SOM PCB No 1397 0 PCB PCB No 1405 0 Edition March 2014 PHYTEC Embedded Pvt Ltd 2014 1...

Страница 2: ...ility for damages arising from the improper usage or improper installation of the hardware or software PHYTEC Embedded Pvt Ltd further reserves the right to alter the layout and or design of the hardw...

Страница 3: ...3 TYPES OF SIGNALS 6 PRODUCT CHANGE MANAGEMENT 8 1 INTRODUCTION 8 1 1 HARDWARE OVERVIEW 8 2 PCL 051 PHYCORE AM335X SYSTEM ON MODULE 11 3 ACCESSING THE PHYBOARD WEGA INTERFACES 12 4 LEDS 14 5 FUNCTIONA...

Страница 4: ...ort Package Software delivered with the Development Kit including an operating system Windows or Linux preinstalled on the module and Development Tools CB Carrier Board used in reference to the 1404 0...

Страница 5: ...Type of Signal Description Abbreviation Power Supply voltage PWR Ref Voltage Reference voltage REF USB Power USB voltage USB Input Digital input IN Output Digital output OUT Input with pull up Input...

Страница 6: ...le and or operate these products Moreover PHYTEC products should not be operated without protection circuitry if connections to the product s pin header rows are longer than 3 mm PHYTEC products fulfi...

Страница 7: ...onality or obsolesce of a certain part are evaluated in order to take the right measures in purchasing or within our HW SW design Our general philosophy here is We never discontinue a product as long...

Страница 8: ...as simple as ordering the connectored version PCM 051 and making use of our phyBOARD WEGA AM335x Carrier Board PBA CD 02 or RDK Carrier Board PCM 953 reference schematics A summary of the phyBOARD WEG...

Страница 9: ...phyBOARD Wega AM335x Block Diagram PHYTEC Embedded Pvt Ltd 2014 9...

Страница 10: ...phyBOARD Wega AM335x 1 4 View of the phyBOARD Wega AM335x PHYTEC Embedded Pvt Ltd 2014 10...

Страница 11: ...nts phyCORE boards achieve their small size through modern SMD technology and multi layer design In accordance with the complexity of the module 0402 packaged SMD components and laser drilled Microwav...

Страница 12: ...modular development platform concept includes the following components The phyCORE AM335x module populated by default with the AM3354 processor and all applicable SOM circuitry such as DDR SDRAM Flash...

Страница 13: ...strip X69 Expansion connector 2 30 socket connector X70 A V connector 1 2 20 socket connector X71 A V connector 2 2 8 socket connector X72 Optional 5 V power supply via USB Micro AB connector X73 Ster...

Страница 14: ...ings while the phyBOARD Wega is supplied With power Power Connectors X67 and X72 The phyBOARD Wega is available with three different power supply connectors Depending on your order you will find one o...

Страница 15: ...X Connector atX67 5 1 2 USB Micro AB If your board provides an USB Micro AB female connector at the upper side of the board a standard USB Micro power supply with 5 V DC can be used to supply the phyB...

Страница 16: ...f the 6 pole WAGO Connector at X67 5 2 Power LED D58 The red LED D58 right next to the power connector indicates the presence of the 3 3 V supply voltage generated from the 5 V input voltage 5 3 VBAT...

Страница 17: ...Wega Am335x Kit to facilitate the use of the UART1 interface The following figure shows the signal mapping of the adapter 5 5 Ethernet Connectivity X16 andX17 The Ethernet interfaces of the phyBOARD...

Страница 18: ...SB Interfaces LED D8 displays the status of USB0_VBUS and LED D7 the status of USB1_VBUS For later expansion boards the USB1 interface can be routed to the expansion connector X69 by populating J72 an...

Страница 19: ...o applications the McASP0 interface of the AM335x including the signals X_MCASP0_AHCLKX X_I2S_CLK X_I2S_FRM X_I2S_ADC and X_I2S_DAC are routed to the A V connector 5 8 CAN Connectivity The CAN1 interf...

Страница 20: ...Digital Memory Card Multimedia Card X11 SD MM Card interface at connector X11 he phyBOARD Wega provides a standard micro SDHC card slot at X11 for connection to SD MMC interface cards It allows easy a...

Страница 21: ...y conflicts when connecting external I 2 C devices to the phyBOARD Wega the addresses of the on board I2C devices must be considered Table 11 lists the addresses already in use The table shows only th...

Страница 22: ...Signal Name Description Pin Ball no of Processor 1 GND Ground 2 X_LCD_D21 LCD D21 T11 3 X_LCD_D18 LCD D18 R12 4 X_LCD_D16 LCD D16 U13 5 X_LCD_D0 LCD D0 R1 6 GND Ground 7 X_LCD_D1 LCD D1 R2 8 X_LCD_D2...

Страница 23: ...Description Pin Ball no of Processor 1 X_I2S_CLK I S Clock A13 2 X_I2S_FRM I S Frame B13 3 X_I2S_ADC I S Analog Digital converter microphone D12 4 X_I2S_DAC I S Digital Analog converter speaker D13 5...

Страница 24: ...X_SPI0_MISO SPI 0 master input slave output B16 8 X_SPI0_CLK SPI 0 clock output A17 9 GND Ground 10 X_UART0_RXD UART 0 receive data standard debug interface E15 11 X_I2C0_SDA I C 0 Data C17 12 X_UART0...

Страница 25: ...to power fail signal through R415 C14 43 nRESET_IN Push button reset A10 44 X_GPIO3_8 GPIO 3_8 Caution Also connected to power down circuit through R412 B14 45 X_AM335_NMIn AM335x non maskable interru...

Страница 26: ...trial Humidity 95 r F not condensed Operating Voltage 5VDC 5 Power Consumption 2 05W typ Linux booted from Micro SD card running ping test 9 Revision History Table 15 Revision History Date Version Num...

Страница 27: ...10 PLACMENT DIAGRAMS Figure 16 Placement Diagram of phyBOARD WEGA AM335x Top Placement Diagram of phyBOARD WEGA AM335x PHYTEC Embedded Pvt Ltd 2014 27...

Страница 28: ...ram of phyBOARD WEGA AM335x Note If you want more information about mechanical dimensions please visit the this FTP link ftp ftp phytec de pub Products phyBOARD WEGA AM335x Layout PL1397_0 PHYTEC Embe...

Страница 29: ...ny PHYTEC Messtechnik GmbH Robert Koch Stra e 39 D 55129 Mainz Tel 49 6131 9221 32 Fax 49 6131 9221 33 www phytec de www phytec eu America PHYTEC America LLC 203 Parfitt Way SW Suite G100 Bainbridge I...

Отзывы: