miniMODUL-537
14
PHYTEC Meßtechnik GmbH 2001 L-006e_2
A37/ PWR Protected_Write (Write-pulse buffered, can be turned off)
Output active LOW. This signal corresponds to the /WR-signal, but
can be disabled by a RESET of the M-DIS-function. For missing
supply voltage, this signal has battery voltage and can therefore be
used for external components with battery buffering.
A61 /RESIN
RESET-Input
Input active LOW. A connection with GND for about .5 sec. triggers a
RESET-pulse. Permanent connection causes a cyclic RESET-pulse
series of 1.6 sec duration. This input is not appropriate to stop the
controller for the duration of the activation of /RESIN.
A34 /RES RESET-Input/Output
Input/Output active LOW. This bi-directional connection might be
connected to GND. For the duration of this connection the controller
remains in the status of a continued RESET. The actuation of the /RES
should be bounce free. The slope of rising edge depends on the load
capacity.
A33 RES RESET-pulse output
Output active HIGH. This signal provides the inverse RESET-pulse of
/RES.
Attention:
An external RESET by wiring of A35 (/RES) doesn’t generate a signal
at A33. Only the RESET-pulses triggered by A61 will be present.
A13 BRESBattery-supplied RESET-signal
Output active HIGH. This signal is the inverse of /RES.
Содержание miniMODUL-537
Страница 1: ...A product of a PHYTEC Technology Holding company miniMODUL 537 Hardware Manual Edition November 1993...
Страница 6: ...miniMODUL 537 PHYTEC Me technik GmbH 1993 L 006e_2...
Страница 24: ...miniMODUL 537 18 PHYTEC Me technik GmbH 2001 L 006e_2 Figure 3 The terminals of the miniMODUL 537...
Страница 38: ...miniMODUL 537 32 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 52: ...miniMODUL 537 46 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 56: ...miniMODUL 537 50 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 58: ...miniMODUL 537 52 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 66: ...Published by PHYTEC Me technik GmbH 2001 Ordering No L xxxe_x Printed in Germany...