miniMODUL-537
4
PHYTEC Meßtechnik GmbH 2001 L-006e_2
2.1
The Serial Interface
If an EPROM was installed by the manufacturer, usually all jumpers
are configured properly. In order to communicate with our Monitor-
program or Monitor-Basic, the connections of the RS-232 interface
A45, A47 with a terminal or PC/AT are required. Those programs
don’t use handshake-lines, since they are operating with XON/XOFF
protocol. Connect the RS-232-input A45 with the RS-232-output of
your PC/AT or terminal and the RS-232-output A47 with the
corresponding input of the terminal or PC/AT. The standard RS-232
connection is especially designated on the printing of the circuit board.
The arrows symbolize the flow of the signals. Don’t forget the
GND-connection for example to A63.
The standard baud rate is 9600 baud. The transmission format is
8 data bit, no parity, one start bit and one stop bit.
In case of malfunctioning, check if RxD and TxD are exchanged. With
a usual voltage meter you can measure, if at the TxD-connection a
negative voltage between –7 V ..-12 V against GND is found. RxD
has a voltage of 0 V against GND.
Please connect always TxD with RxD and RxD with TxD. If
sometimes the transmission is failing, the GND-line might be
connected in the wrong way.
Содержание miniMODUL-537
Страница 1: ...A product of a PHYTEC Technology Holding company miniMODUL 537 Hardware Manual Edition November 1993...
Страница 6: ...miniMODUL 537 PHYTEC Me technik GmbH 1993 L 006e_2...
Страница 24: ...miniMODUL 537 18 PHYTEC Me technik GmbH 2001 L 006e_2 Figure 3 The terminals of the miniMODUL 537...
Страница 38: ...miniMODUL 537 32 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 52: ...miniMODUL 537 46 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 56: ...miniMODUL 537 50 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 58: ...miniMODUL 537 52 PHYTEC Me technik GmbH 2001 L 006e_2...
Страница 66: ...Published by PHYTEC Me technik GmbH 2001 Ordering No L xxxe_x Printed in Germany...